Site Survey Form Generic Format - Coastal Environmental Systems

Site Survey Form Generic Format - Coastal Environmental Systems

Site Survey Form Generic Format - Coastal Environmental Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SITE SURVEY REPORT – location name9. RLIM PASSIVE / ACTIVE RUNWAY REQUIREMENTSSee RLIM - Passive Layout, following, for siting of Passive RLIM and requiredpower and comm connections.PowerComm –copperActiveRunwaymonitoringActiveRunwaymonitoringEdgewaylightmonitoringEdgewaylightmonitoringRLIM lightingequipmentconnectionRLIM CurrentClamp TypesSpaceRequirement Existing Action By<strong>Site</strong>NoneInstall atlocationshownOne dedicated 120 VAC 15 Ampcircuit, terminated in coveredelectrical junction box within 6 ft ofRLIMTwo unconditioned 24 AWG or largertwisted copper pairs, terminated inRJ-45 wall jack within 6 ft of RLIM,connected to DPU punchdown blockTwo 20-gauge wires (Contractorprovided)run between RLIM locationand each current clamp location.One ½” EMT or rigid conduit needs tobe run from the sited RLIM location tothe PAPI Regulator clamp locationOne 20-gauge wire (Contractorprovided)run between RLIM locationand each current clamp location.One ½” EMT or rigid conduit needs tobe run from the sited RLIM location tothe Edge Lights Regulator clamplocationCT Clamps will be required at thislocation.Edgeway: 1 @ 6.6 AmpApproach: 2 @ 6.6 AmpTo accommodate 12” x 20” wallmounted enclosureNoneInstall atlocationshownAction ByContractorNone None Provide cableNoneInstall atlocationshownPull cablesthroughexistingconduitNone None Provide cableNoneNoneGround Base-approved ground OKOKInstall atlocationshownBase CEmount CTclamps.Reservelocation tothe left ofexisting FAARLIMPull cablethroughexistingconduitAssist baseCE withmounting CTclamps.Contractor toprovide CTclamps• Proposed or expected changes to lighting vault or equipment: None• Vault or RLIM mounting location wall material type: Concrete block wall. Tin siding. Uni-strutrequired to mount RLIM to Tin siding• Other:oThe maximum cable distance the passive RLIM can be located from the clamp devicerequired for current monitoring is 150 feet.<strong>Site</strong> <strong>Survey</strong> <strong>Form</strong> <strong>Generic</strong> <strong>Form</strong>at 6-25-13.docPage 14© 2013 <strong>Coastal</strong> <strong>Environmental</strong> <strong>Systems</strong>, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!