SITE SURVEY REPORT – location nameTherefore, the optic signal level loss has to be determined at the END POINTS of the fiber opticlink.The signal loss for IFS D1000 line drivers should be less or equal to the values listed in the belowtable:Fiber Optic CableTypeMulti-mode *62.4/125 µmMulti-mode *62.5/125 µmSingle-mode9/125 µmFiber OpticLine DriverModelD1010D1020D1030DescriptionRS-232Transceiver 850 nmRS-232Transceiver 1310 nmRS-232Transceiver 1310 nmMaximal SignalLoss11 dB10 dB17dB* For 50/125 µm fiber subtract 4 dB from the Maximal Signal Loss.Decibel Loss Test ResultsRevise Table as requiredTest PointsPrimary FDCU to DPUDiscontinuity FDCU to DPURLIM to DPUMax dBLoss17 db17 db17 dbActual dBLossPass/Fail<strong>Site</strong> <strong>Survey</strong> <strong>Form</strong> <strong>Generic</strong> <strong>Form</strong>at 6-25-13.docPage 20© 2013 <strong>Coastal</strong> <strong>Environmental</strong> <strong>Systems</strong>, Inc.