Section C - Components, cont’d.C16e.Relay, SPDT (single pole/double throw) is used on Models39424.601, 39115.626,39125.601, 39335.601 and39335.636.On Model 39424.601 it is used to complete 115 volt ACcircuit to Circuit 2 compressor. On Models 39115.626,39125.601, 39335.601 and 39335.636 it is a furnace blowerrelay.The relay has a 115 volt AC coil.Terminals 1 and 3 are the coil terminals. When the coil(terminals 1 and 3) is NOT energized (no power to terminals1 and 3), continuity should exist between terminals 4to 5; and no continuity between terminals 2 to 4.When the coil (terminals 1 and 3) is energized (power toterminals 1 and 3), continuity should exist between terminals2 to 4 and no continuity between terminals 4 to 5.FIG. C26C16g.Relay, SPDT (single pole/double throw) is used onModels 39115.XXX, 39325.XXX,39335.XXX and 39424.601.On Models 39115.XXX, it controls HIGH and LOW FANspeeds. On Models 39325.XXX, 39335.XXX and39424.601, it opens the control circuit for the fan motorwhen the coil is energized.Note: Incorrect wiring to the thermostat can energize therelay coil on heat pump models 39325.XXX, 39335.XXXand 39424.601.The relay has a DC volt coil. To check the relay, first verifyall AC volts have been turned off to the unit.Next, remove the wires from COM and NC terminals. Verifythe relay coil is not energized (no DC power). Continuityshould exist between terminals COM and NC and no continuitybetween terminals COM and NO. Next, energize therelay coil with DC volts (<strong>10</strong> to 16). Continuity should existbetween terminals COM and NO and no continuity betweenCOM and NC. If the above checks are correct, the relay isgood - DO NOT replace it. If the above checks are notcorrect, the relay is defective and should be replaced.FIG. C28C16f.Relay, SPDT (single pole/double throw) is used onModels 39325.XXX and39335.XXX.On Model 39325.XXX it is used to complete the 115 voltAC circuit to the reversing valve.On Model 39335.XXX is used to complete the 115 volt ACcircuit to the reversing valve and to the furnace blower relaycoil. The relay has a DC volt coil.Terminals 1 and 3 are the coil terminals. When the coil(terminals 1 and 3) is NOT energized(no power to terminals 1 andFIG. C273), continuity should exist betweenterminals 4 to 5; and no continuitybetween terminals 2 to 4. When thecoil (terminals 1 and 3) is energized(power to terminals 1 and 3), continuityshould exist betweenterminals 2 to 4 and no continuitybetween terminals 4 to 5.C16h.Relay (9T91/120V)(SPDT)The relay is used on basement air conditioner Model 39224and basement heat pump Model 39424 ONLY.The relay has five terminals. Two terminals are not identified;they are the coil terminals. When the coil is not energized(no power to the coil terminals), continuity shouldexist between COM and NC and no continuity betweenCOM to NO.When the coil is energized (power to the coil terminals),continuity should exist between COM to NO and no continuitybetween COM to NC.FIG. C2936

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!