Section C - Components, cont’d.To check ACTIVE terminals, place one lead from ohm meterto R terminal and the other lead to the ACTIVE terminal.SWITCH IF ROOM TEMP.COMB. IS ABOVE/BELOW TERMINALS THATFAN SETPOINT TEMP. ARE “ON”SWITCH G YAUTO ABOVE X XBELOWON ABOVE X XBELOWXThe heating and cooling thermostat has two switches onthe base. They are HEAT-OFF-COOL on the left side, andFAN-AUTO-ON on the right. This thermostat will operatean air conditioner and a furnace.FIG. C46between RC to Y and RC to G. With FAN switch to ONposition, continuity should exist between RC to G regardlessof room temperature.With HEAT-OFF-COOL switch in the OFF position and FANswitch in the AUTO position, no continuity should exist betweenRC to Y and RC to G regardless of room temperature.With FAN switch to ON position, continuity should existbetween RC to G and no continuity between RC to Y regardlessof room temperature.With HEAT-OFF-COOL switch to HEAT and FAN switch toAUTO position, no continuity should exist between RC to Yand RC to G regardless of room temperature. With FANswitch to ON position, continuity should exist between RCto G and no continuity between RC to Y regardless of roomtemperature. With room temperature below setpoint temperature,continuity should exist between RH to W. Withroom temperature above setpoint temperature no continuityshould exist between RH to W.FIG. C47Verify that the wiring to the thermostat is correct.A three-connector cable 18 to 22 AWG is to be used forlow voltage connections. Low voltage wires in the controlcompartment are marked “R”, “G” and “Y”. Route low voltagecable from thermostat to unit electrical box. Use .50dia. snap-bushing for routing cable into electrical box. SeSection C<strong>19</strong>.Connect RC from thermostat to red wire in control compartment.Connect G or F from thermostat to blue wire incontrol box. Connect Y from thermostat to yellow wire incontrol box. Use wire nuts to ensure good connections.When connecting a gas furnace to this thermostat, the RHand W terminals are used.To check the thermostat remove all wires. Next, using anohm meter, put the HEAT-OFF-COOL switch in the COOLposition. With room temperature above the setpoint temperatureand FAN switch in AUTO position, continuity shouldexist between RC to Y and RC to G. With room temperaturebelow set point temperatures, no continuity should existTo check ACTIVE terminals, place one lead from ohm meterto RC (cooling) or RH (heating) terminal and the other leadto the ACTIVE (ON) terminal.SWITCHCOMBINATIONSYSTEM FANSWITCH SWITCHCOOLHEAT OFFAUTOONAUTOONAUTOONIF ROOM TEMP.IS ABOVE/BELOWSETPOINT TEMP.ABOVEBELOWABOVEBELOWABOVEBELOWABOVEBELOWABOVEBELOWABOVEBELOWTERMINALS THATARE “ON”G Y WX XXXXXXXXXX46

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!