Commissioning and Testing<strong>GEA</strong> <strong>COM4plus</strong>8.3.3 Commissioning of units for outdoor installation (weatherproof roof units)The following procedures for commissioning must be carried out:• First carry out all procedures as described in „Commissioning of units for indoorinstallation“ on page 45.• Checks weatherproof seals (refer to „Foundation construction for outdoorinstallation (weatherproof, roof frame)“ on page 25).8.3.4 Maintenance of units for outdoor installation (weatherproof roof units)The following procedures for maintenance must be carried out:• First carry out all procedures as described in „Maintenance of units for indoorinstallation“ on page 45.• Check tightness of unit roof.• Check side panels and cover strips and renew the seal material in individualcomponents.• Clean weather protection grille for fresh and extract air once a year.Hygiene inspectionObserve current codes andstandards! We recommendmaintenance proceduresand intervals specified in VDI6022.• Check installed components for contamination, clean as necessary.• Carry out disinfection (disinfectant must not attack cleaned materials, only usealcohol-based disinfectant).• Check the sealing materials for mould and fungi. Clean or replace the sealingmaterials as required.8.4 Fan unit and drives8.4.1 Commissioning of fan unitELECTRICAL HAZARD AND DANGER OF ROTATING UNIT PARTS! OBSERVEPERSONAL PROTECTION MEASURESPlease consider the safety instructions on page 41.DAMAGE TO THE UNIT!Do not start up the fan against closed dampers.The following procedures for commissioning must be carried out:• In general check the entire casing and all components for damage and correct seat.• Remove transportation locks.• Check the fan rotation direction at all speed stages.• Measure the motor power consumption. The rated motor current as specified on theidentification plate may not be exceeded in any operating state.• Ensure the proper operation of the motor protection device.• Check and open all system components (air control and shut-off dampers, fireprotection dampers, flow rate controller), ensure their proper operation.46 PR-2009-0022-GB • Subject to modifications • Status 04/2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!