DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
VX.018 - Connect the following<br />
jumpers on the device:<br />
a) ..... with .....<br />
b) ..... with .....<br />
c) ..... with .....<br />
VX.021 - Cut or remove the jumpers on<br />
the device(s):<br />
- ...-...<br />
- ...-...<br />
-...-...<br />
VX.023 - Terminal equivalence:<br />
- RT (Sentry+)= RD (Atlantico).<br />
VX.025<br />
EXAMPLE OF POWER CONNECTION WITH<br />
ATLANTICO <strong>VIDEO</strong> <strong>DOOR</strong> <strong>PHONE</strong>S<br />
R1 R2<br />
R<br />
75<br />
R1<br />
RD<br />
R2<br />
V4<br />
V5<br />
V3<br />
RD<br />
R1<br />
R2<br />
V4<br />
V5<br />
V3<br />
VX.028 - For Ref. 5330/60 only: cut<br />
and isolate wire 1 (red)<br />
NOTE 1: The electrical lock is shown in the diagrams and<br />
must have the following features:<br />
12Vac - 15VA<br />
NOTE 2: The number of devices shown by an X must be<br />
evaluated according to the system type to be made.<br />
<strong>DOOR</strong> <strong>PHONE</strong> - <strong>VIDEO</strong> <strong>DOOR</strong> <strong>PHONE</strong> <strong>SYSTEMS</strong>: <strong>Installation</strong> Diagrams<br />
2<br />
1<br />
INSTALLATION DIAGRAMS<br />
DIAGRAM NOTES<br />
VX.031 - On the device remove<br />
the jumper P1 which short circuit<br />
the diode 1N4700. In intercom system<br />
there is not necessary connect the<br />
diode.<br />
VX.032 - MINIME WIRE CROSS<br />
SECTION AREAS<br />
The section area and the voltage cable<br />
(12Vcc 12Vdc)lenght are in function<br />
of the camera intake.<br />
See the following table:<br />
Camera<br />
intake<br />
max 300mA<br />
Camera<br />
intake<br />
Cross section<br />
area(mmq)<br />
0,75<br />
1,5<br />
2,5<br />
4<br />
Cross section<br />
area(mmq)<br />
Distance<br />
(m)<br />
50<br />
100<br />
150<br />
240<br />
VX.033 - MINIME WIRE CROSS<br />
SECTION AREAS<br />
The section area and the voltage cable<br />
(12Vcc 12Vdc)lenght are in function<br />
of the camera intake.<br />
See the following table:<br />
max 500mA<br />
Distance<br />
(m)<br />
1<br />
50<br />
2,5<br />
125<br />
4 200<br />
VX.034 - MINIME WIRE CROSS SECTION AREAS<br />
Distance m<br />
Normal<br />
wires<br />
Call and<br />
button<br />
common<br />
wires<br />
Wires<br />
R1, R2, +TC<br />
COAXIAL<br />
CABLE<br />
75 Ohm<br />
mmq<br />
mmq<br />
mmq<br />
50<br />
100<br />
0,5 0,5 0,8 1<br />
VU.002 - Follow the instructions<br />
provided with the product for<br />
fitting the camera.<br />
200 300<br />
0,5 0,8 1 1,6<br />
0,5 0,5 0,8 1<br />
Use a normal coaxial wire<br />
for distances up to 300 m<br />
Add a video amplifier for<br />
longer distances.<br />
Use two wires for lighting the panel<br />
name tags if not included in the diagram.<br />
Use a separate transformer of suitable<br />
power.<br />
Transformer ref. 9000/230 is recommended<br />
for up to 15W-<br />
The system power unit is sufficient for<br />
up to 6W.<br />
sec.1 −−−− 11<br />
INSTALLATION DIAGRAMS