24.11.2012 Views

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY<br />

REPLACING RELAY BOX Ref. 9332/8 AND Ref. 788/8 WITH Ref. 788/58<br />

REPLACING 12VAC TRANSFORMER Ref. 9000/20 WITH Ref. 9000/230<br />

REPLACING RELAY BOX Ref. 9332/8 AND Ref. 788/8 WITH Ref. 788/58<br />

The Ref. 788/58 relay box can replace the obsolete 9332/8 and 788/8 model.<br />

The terminals correspond as follows:<br />

Note : Terminals C1, C2, ~12 of relay Ref. 788/58 must be connected together by jumpers and connected to ~12.<br />

REPLACING 12VAC TRANSFORMER Ref. 9000/20 WITH Ref. 9000/230<br />

The 9000/230 transformer can replace the obsolete 9000/20 model.<br />

The terminals correspond as follows:<br />

(∗) Not available in Italy.<br />

POWER<br />

OUTPUTS<br />

Ref. 9332/8 Ref. 788/8<br />

1<br />

1<br />

2<br />

-<br />

AP<br />

1 I<br />

2 I<br />

- I<br />

AP I<br />

1 II<br />

2 II<br />

- II<br />

AP II<br />

1 III<br />

2 III<br />

- III<br />

AP III<br />

1 IV<br />

- IV<br />

2 IV<br />

AP IV<br />

SN1<br />

SN2<br />

SN3<br />

SN4<br />

A<br />

B ♦<br />

2<br />

-<br />

AP<br />

1 I<br />

2 I<br />

- I<br />

2 II<br />

1 II<br />

AP I<br />

- II<br />

1 III<br />

AP II<br />

2 III<br />

- III<br />

AP III<br />

1 IV<br />

2 IV<br />

- IIV<br />

AP IV<br />

SN1<br />

SN2<br />

SN3<br />

SN4<br />

~0<br />

~12<br />

C1<br />

C2<br />

Ref. 788/58<br />

1<br />

18 −−−− sec.1f <strong>DOOR</strong> <strong>PHONE</strong> - <strong>VIDEO</strong> <strong>DOOR</strong> <strong>PHONE</strong> <strong>SYSTEMS</strong>: <strong>Installation</strong> Diagrams<br />

2<br />

-<br />

AP<br />

1 I<br />

2 I<br />

- I<br />

2 II<br />

1 II<br />

AP I<br />

- II<br />

1 III<br />

AP II<br />

2 III<br />

- III<br />

AP III<br />

1 IV<br />

2 IV<br />

- IIV<br />

AP IV<br />

SN1<br />

SN2<br />

SN3<br />

SN4<br />

~0<br />

~12<br />

C1<br />

C2<br />

Ref. 9000/20 Ref. 9000/230<br />

~0<br />

0<br />

~110 Not available<br />

~220<br />

~230<br />

~240 Not available<br />

~0<br />

~0<br />

~12<br />

~12<br />

Ref. 9000/110 (∗)<br />

0<br />

~110<br />

Not available<br />

Not available<br />

~0<br />

~12