DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation - Urmet
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TO THE FOLLOWING<br />
MODULE<br />
Name tag<br />
lighting<br />
~12<br />
~0<br />
~0<br />
~12<br />
G/T<br />
G/T<br />
~12<br />
~0<br />
~0<br />
~12<br />
~12<br />
~0<br />
~0<br />
~12<br />
G/T<br />
G/T<br />
~12<br />
~0<br />
~0<br />
~12<br />
~12<br />
~0<br />
~0<br />
~12<br />
G/T<br />
G/T<br />
~12<br />
~0<br />
~0<br />
~12<br />
ELECTRIC<br />
LOCK<br />
(C4.007)<br />
(C4.008)<br />
(C4.017)<br />
G/T<br />
U4<br />
U3<br />
U2<br />
U1<br />
L<br />
1A 2<br />
U4<br />
U3<br />
U2<br />
U1<br />
G/T<br />
G/T<br />
U4<br />
U3<br />
U2<br />
U1<br />
U4<br />
U3<br />
U2<br />
U1<br />
G/T<br />
G/T<br />
U4<br />
U3<br />
U2<br />
U1<br />
U4<br />
U3<br />
U2<br />
U1<br />
G/T<br />
+<br />
1<br />
DIAGRAM NOTES<br />
(see section 1)<br />
C4.001<br />
C4.006<br />
Sinthesi models only:<br />
Connect jumper L with G/T.<br />
C4.007 C4.008 C4.017<br />
-<br />
CONNECTION OF SEVERAL COLUMNS OF <strong>DOOR</strong> <strong>PHONE</strong>S<br />
TO 1 MAIN OUT<strong>DOOR</strong> STATION<br />
Each column is also connected to its own secondary outdoor station.<br />
Use the relay box Ref. 788/51 and the power supply Ref. 786/11<br />
Lock<br />
Release<br />
RELAY<br />
BOX<br />
~12<br />
~0<br />
S3<br />
S1 2<br />
CA<br />
<strong>DOOR</strong> <strong>PHONE</strong> - <strong>VIDEO</strong> <strong>DOOR</strong> <strong>PHONE</strong> <strong>SYSTEMS</strong>: <strong>Installation</strong> Diagrams<br />
S2 C6<br />
~ + - ~<br />
12 6 6 0<br />
PS<br />
CA<br />
1<br />
2<br />
6<br />
9<br />
10<br />
CA<br />
1<br />
2<br />
6<br />
9<br />
10<br />
~ ~ PS ~ - + ~<br />
0 6 6 12<br />
~ ~<br />
RELAY<br />
BOX<br />
10<br />
11<br />
12<br />
SN1<br />
1<br />
4<br />
C2 ~<br />
14<br />
7<br />
C1<br />
0<br />
MAIN ~<br />
MAIN ~<br />
8 5 2<br />
SN2<br />
3<br />
6<br />
13<br />
9<br />
15<br />
~<br />
12<br />
POWER SUPPLY FOR<br />
<strong>DOOR</strong> <strong>PHONE</strong> SYSTEM<br />
1ST COLUMN 2ND COLUMN<br />
(C4.006)<br />
Lock<br />
Release<br />
POWER SUPPLY FOR<br />
<strong>DOOR</strong> <strong>PHONE</strong> SYSTEM<br />
(C4.007)<br />
(C4.008)<br />
(C4.017)<br />
G/T<br />
U4<br />
U3<br />
U2<br />
U1<br />
U4<br />
U3<br />
U2<br />
U1<br />
G/T<br />
L<br />
1A<br />
2<br />
-<br />
+<br />
1<br />
TO THE FOLLOWING<br />
MODULE<br />
~12<br />
~0<br />
~0<br />
~12<br />
G/T<br />
G/T<br />
~12<br />
~0<br />
~0<br />
~12<br />
ELECTRIC LOCK<br />
Name tag<br />
lighting<br />
SN1<br />
SC101-1240A<br />
CONNECTION<br />
AS 1ST GROUP<br />
1<br />
4<br />
-6<br />
7<br />
C1<br />
SN1<br />
Calls<br />
1<br />
4<br />
-6 Common<br />
7<br />
C1<br />
TO THE FOLLOWING<br />
GROUP<br />
sec.1a−−−− 17<br />
<strong>DOOR</strong> <strong>PHONE</strong> <strong>SYSTEMS</strong><br />
BASIC SYSTEM DIAGRAMS