11.07.2015 Views

User Manual - Hasselblad.jp

User Manual - Hasselblad.jp

User Manual - Hasselblad.jp

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

H4D2. Fold the tissue several times to match the width of the IR filter—you might use twoor three tissues at a time if necessary (to give you a better grip). Be sure to fold thepaper so that the coated glossy side faces outwards—do not use the other side, as itcan do more harm than good!3. Gently place the folded tissue onto the edge of the filter using two or three fingers.Be sure to wipe the entire surface evenly. Sweep the filter only once. Do not wipe thesame area twice with the same tissue as you might reapply dirt removed in the firstsweep.4. Finally check if the IR filter has been properly cleaned either by visual inspection orby mounting the digital capture unit to the camera and making a shot. If furthercleaning is needed, repeat cleaning procedure.Cleaning with an E-WipeE-wipes are individually packed wet tissues.1. Tear at the notch to break seal.2. Remove e-wipe from its packaging and continue without delay.3. Fold the tissue to match the width of the IR filter.4. Apply firm pressure using two or three fingers at the edge of the wipe to ensure aneven, firm contact with filter surface. Wipe the surface in one unbroken motion. Note! Do not use same side of the e-wipe twice as you will be likely to reapply any particlesremoved in the first pass.5. Finally check if the IR filter has been properly cleaned either by visual inspection orby mounting the digital capture unit to the camera and making a shot. If furthercleaning is needed, repeat cleaning procedure.Attaching the digital capture unitPosition the digital capture unit retention groove onto the digital capture unit supporton the camera body ensuring that they are correctly positioned. Swing the digital captureunit towards the camera body and firmly press into place with a click. If there isresistance, the magazine retaining catch on the camera has probably been inadvertentlyreleased. In that case, push the release button again to reset the catch.Cleaning the housingsIf the camera becomes dirty, clean it with a soft, clean cloth lightly moistened with wateronly. Do not use any other solvents and do not allow water to seep in the openings.137

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!