11.07.2015 Views

technical service guide new 30" xl44™ series ... - Appliance Blog

technical service guide new 30" xl44™ series ... - Appliance Blog

technical service guide new 30" xl44™ series ... - Appliance Blog

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CONVERSION & ORIFICES INFORMATIONLoosenBAKE BURNERADJUSTMENTSAir AdjustmentShutterBROIL BURNERADJUSTMENTSAir AdjustmentShutterLoosen6 Open the bake and broil air shutter adjustments as far as possible and adjust later if necessary.Beneath the bake and broil burner orifice hoods are LP orifice needles. To convert to L.P. tighten the orifice hoodsagainst the orifice needle until the hoods are snug (2-2½ turns). DO NOT OVER TIGHTEN. Check the burners forproper flame adjustment. The burner flame should have approximately 1" blue cones. With most LP gas, smallyellow tips at the end of outer cones are normal. flames should not lift off burner ports. If lifting is observed,gradually reduce the air shutter opening until flames are stabilized.ORIFICE INFORMATIONJGBP85BEA Orifice ChartsBURNER OUTPUT RATINGS; BTU/HRNATURAL GAS with 4" W.C.P.TOP BURNER ORIFICESBURNER OUTPUT RATINGS; BTU/HRLP (PROPANE) GAS with 10" W.C.P.Burner BTU Rate Orifice SizeLF, RF 12,000 1.68 mm (III)LRRRBurner BTU Rate Orifice SizeLF, RF 11,000 .94L mm (III)LR 9,500 1.50 mm (II)LFRFLR 9,500 .89L mm (II)RR 5,000 1.07 mm (I)BAKE 16,000 #47 (.0785")BROIL 13,500 (.069")Front of RangeLPGASRR 5,000 .63L MM (I)BAKE 16,000 #56 (.0465")BROIL 12,000 #59 (.041")175IIINNatural gas surfaceorifices are markedon top as shownThe top burner orifices each have a <strong>series</strong> of marks engraved on thetops of the orifices (I, II, III) to denote their location. The marksappear on both the Natural and LP gas orifices. The locationindicated by the marks, is the same for both gases.See BURNER OUTPUT RATING charts at right for locations.90 LP gas surfaceorifices are markedIIIon top as shownLSMALLER ORIFICES FOR HIGHER ELEVATIONSBurner Size Part Number L.P. NaturalLF & RF 1.65 mm WB02X9841LF & RF .84 mm WB02K0022LR 1.44 mm WB06K0094LR .73 mm WB19K5000IMPORTANT NOTE: Always consult the Technical Serviceliterature (mini-manual) enclosed with the appliance for modelspecific conversion informationLP ORIFICE COLOR IDBurner BTU Rate ColorLF & RF 11,000 BTU Blue / MagentaLR 9,500 BTU Blue / BrownRR 5,000 BTU Blue / BluePaint color codes have been added to thesides of the LP orifices to aid in identifyingthe proper orifice location during conversion.– 12 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!