4. The control board is not sending power to the igniter. Check the voltage going to the igniter during ignition. It should be afull current. If the voltage is lower than full current, check the wiring.If the wiring is functional and properly connected, the board isdefective. You will need a technician to perform this test.5. The pump is not connected properly or isn’t working properly Verify that the plug is connected properly and if the pump is runningduring the lightning cycle. If the pump isn’t working make sure allconnections are good.STOVE FEEDS PELLETS, BUT WILL NOT IGNITE ANDPossible Cause:APPEARS ON THE CONTROL BOARDPossible Remedy:1. The igniter fuse on the control board has blown. The igniter or the pump is defective or the wiring harness shorted.Remove the control board cover and check if the F1 fuse appears tohave blown. Replace it with a 5 Amp 250V fuse. Plug the stoveback on and try to start the unit.STOVE FEEDS PELLETS, BUT WILL NOT IGNITE ANDPossible Causes:APPEARS ON THE CONTROL BOARDPossible Remedies:1. The auger jammed, the auger motor is defective or thewiring harness shorted.Remove the control board cover and check if the F2 fuse appears tohave blown. Replace it with a 3 Amp 250V fuse. Plug the stoveback and try to run the unit.2. The auger fuse has blown. Start by emptying the hopper. Then, remove the auger motor byremoving the screws holding the motor to the auger shaft Once themotor is out, remove the four screws on the steel plate holding theauger shaft to the auger housing. Then, rotate the bottom end of theauger shaft down towards you until you can pull the shaft down outof the stove. After you have removed the shaft, inspect it for bentflights, burrs, or broken welds. Remove any foreign material thatmight have caused the jam. Also, check the auger housing for signsof damage such as burrs, rough spots, or grooves cut into the metalthat could have caused a jam. Clean the auger housing thoroughlyto remove all pellet dust. Repeat the process whit the burn pot augermotor.STOVE STOPS FEEDING PELLETS ANDPossible Cause:APPEARS ON THE CONTROL BOARDPossible Remedy:1. An overheat zone was detected on the auger housing The L-250 automatic high temperature switch is located on the top ofthe auger housing. It sends a signal to the control board if the augerhousing overheats. Wait until the stove cools down AND THENINSPECT YOUR UNIT. Improper installation, poor maintenance, or adefective or missing component may be causing the stove tooverheat. Reset the stove and restart it. Call a technician if you getthis code again.*** After 3 attempts, reset is no longer possible, call SBI technical support.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!