12.07.2015 Views

FX3U-ENET-L USER'S MANUAL - Automation Systems and Controls

FX3U-ENET-L USER'S MANUAL - Automation Systems and Controls

FX3U-ENET-L USER'S MANUAL - Automation Systems and Controls

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3SPECIFICATIONSMELSEC-F(f) Open/close control (BFM #1600 to 1663)BFM numberDecimal(Hexadecimal)Attribute Application NameInitial valueDecimal(Hexadecimal)Flash ROMsaveReferencesection• Write valueRe-initialization request0001H : Re-initialization ([COM.ERR.] LED OFF)1600(640H)R/WRe-initialization0002H : Re-initialization after reading data in Flash ROM([COM.ERR.] LED OFF)0005H : Re-initialization ([COM.ERR.] LED retains status.)0006H : Re-initialization after reading data in Flash ROM([COM.ERR.] LED retains status.)• Read value0008H : During re-initialization8000H : At re-initialization completionC000H : At re-initialization error• In the re-initialization st<strong>and</strong>by, the write value is read directly.0(0000H)—1601(641H)R/WCOM.ERR.Off[COM.ERR.] Off request• Write value0001H: [COM.ERR.] LED Off request• Read value0002H: Stores at normal completion• 0001H is read while ready until LED OFF operation starts0(0000H)—1602(642H)R/WFor open/closecontrolOpen/Closecomm<strong>and</strong>/statusConnection No.1 Open/Close comm<strong>and</strong>• Write value0001H: Open comm<strong>and</strong>8000H: Close comm<strong>and</strong>• Read valueb0=0 : Open comm<strong>and</strong> enabledb0=1 : Open comm<strong>and</strong> disabled0000H : Close status(Including when FIN is sent fromthe external device)0003H : Open request or Listen being processed(b1, b0: ON)0005H : Open status (b2, b0: ON)0009H : Close request being processed(b3, b0: ON)0010H : Open error (Closed status) (b4: ON)0015H : Open error (Open status) (b5: ON)0001H : During open st<strong>and</strong>by8000H : During close st<strong>and</strong>by0(0000H)Chapter 51603(643H)1604(644H)1605(645H)1606 to 1609(646 to 649H)R/W Connection No.2 Open/Close comm<strong>and</strong> (Same as connection No.1)R/W Connection No.3 Open/Close comm<strong>and</strong>* 1 (Same as connection No.1)R/W Connection No.4 Open/Close comm<strong>and</strong>* 1 (Same as connection No.1)— System area — — —(Continues on the next page)*1 Required only when MC protocol is set.3 - 183 - 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!