1-6 Using the <strong>Model</strong> Kit Component in <strong>SoC</strong> <strong>Designer</strong>1.4 Setting Component ParametersYou can change the settings of all the component parameters in <strong>SoC</strong> <strong>Designer</strong> Canvas, andof some of the parameters in <strong>SoC</strong> <strong>Designer</strong> Simulator. To modify the <strong>Carbon</strong> component’sparameters:1. In the Canvas, right-click on the <strong>Carbon</strong> component and select Edit Parameters....You can also double-click the component. The Edit Parameters dialog box appears.Figure 1-2 Component Parameters Dialog Box2. In the Parameters window, double-click the Value field of the parameter that youwant to modify.<strong>Carbon</strong> Design Systems, Inc. Confidential
Setting Component Parameters 1-73. If it is a text field, type a new value in the Value field. If a menu choice is offered,select the desired option. The parameters are described in Table 1-3.Table 1-3 Component ParametersNameDescriptionAllowedValuesDefault Value Runtime 1Align Wave<strong>for</strong>ms<strong>Carbon</strong> DB PathDump Wave<strong>for</strong>msEnable Debug Messagesresetnresetn_rWhen set to true, wave<strong>for</strong>msdumped from the <strong>Carbon</strong> componentare aligned with the <strong>SoC</strong><strong>Designer</strong> simulation time. The resetsequence, however, is not includedin the dumped data.When set to false, the resetsequence is dumped to the wave<strong>for</strong>mdata, however, the <strong>Carbon</strong>component time is not aligned withthe <strong>SoC</strong> <strong>Designer</strong> time.Sets the directory path to the <strong>Carbon</strong>database file.Whether <strong>SoC</strong> <strong>Designer</strong> dumpswave<strong>for</strong>ms <strong>for</strong> this component.Whether debug messages arelogged <strong>for</strong> the component.Sets the value <strong>for</strong> the specifiedReset signal, or signals, correspondingto the specified clockdomain.If a resetn_rsignal exists, this parameter sets thevalue <strong>for</strong> the specified Reset signal,or signals, corresponding to thespecified clock domain._ Sizes of memory regions. 0x0 -size[0-5] 2 0x100000000true, false true NoNot Used empty Notrue, false false Yestrue, false false Yes0x0, 0x1 0x1 Yes0x0, 0x1 0x1 Yessize0 default is0x100000000,size1-5 defaultis 0_ Start addresses of memory regions. 0x0 - 0xffffffff 0x00000000 Nostart[0-5] 2Enable Debug MessagesEnable Debug MessagesWhether debug messages arelogged <strong>for</strong> the master ports. Thereis one parameter <strong>for</strong> each masterport.Whether debug messages arelogged <strong>for</strong> the slave ports. There isone parameter <strong>for</strong> each slave port.Notrue, false false Yestrue, false false Yes<strong>Carbon</strong> Design Systems, Inc. Confidential