12.07.2015 Views

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s Manual1. INSTALLATION1.1 Introduction to the Control PanelThe <strong>DKG</strong>-<strong>705</strong> is a control and protection unit used in gensets. The 4 lines by 20 characters LCDdisplay allows the visualization of many measured parameters. The unit is designed to provide userfriendliness for both the installer and the user. Programming is usually unnecessary, as the factory settingshave been carefully selected to fit most applications. However programmable parameters allow thecomplete control over the generating set. Programmed parameters are stored in a Non Volatile Memoryand thus all information is retained even in the event of complete loss of power.The measurable parameters are:Mains voltage phase R to neutralMains voltage phase S to neutralMains voltage phase T to neutralMains voltage phase R-SMains voltage phase S-TMains voltage phase T-RMains current phase R (optional)Mains current phase S (optional)Mains current phase T (optional)Mains frequencyMains KW phase R (optional)Mains KW phase S (optional)Mains KW phase T (optional)Mains KVA phase R (optional)Mains KVA phase S (optional)Mains KVA phase T (optional)Mains KVAr phase R (optional)Mains KVAr phase S (optional)Mains KVAr phase T (optional)Mains cos? phase R (optional)Mains cos? phase S (optional)Mains cos? phase T (optional)Mains total KW (optional)Mains total KVA (optional)Mains total KVAr (optional)Mains total cos? (optional)Gen voltage phase U to neutralGen voltage phase V to neutralGen voltage phase W to neutralGen voltage phase U-VGen voltage phase V-WGen voltage phase W-UGen current phase UGen current phase VGen current phase WGen frequencyGen KW phase UGen KW phase VGen KW phase WGen KVA phase UGen KVA phase VGen KVA phase WGen KVAr phase UGen KVAr phase VGen KVAr phase WGen cos? phase UGen cos? phase VGen cos? phase WGen total KWGen total KVAGen total KVArGen total cos?Synchronoscope phase angleVoltage match U-RBattery voltage,Engine RPMCoolant temperatureOil pressureOil temperatureFuel level<strong>705</strong>-UE.doc - 3 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!