DATAKOM<strong>DKG</strong>-<strong>705</strong> User’s Manual2. INPUTS <strong>AND</strong> OUTPUTS12V JUMPER: When this jumper is placed, 12V-DC operation is selected. Do not operate a 12V-DC unit witha 24V-DC system. This may cause the destruction of the unit. Always disconnect the voltage selector jumperof a stocked unit.RS-232 SERIAL PORT: This connector provides serial data input and output for various purposes likesoftware update, remote monitoring, remote control, remote programming, etc.EXTENSION CONNECTOR (OPTIONAL): This connector is intended for the connection of input and outputextension modules. The optional relay extension module provides 8 programmable 16A relay outputs. The<strong>DKG</strong>-<strong>705</strong> allows the use of up to 2 I/O extension modules.Term Function Technical data Description1 GENERATOR CONTACTOR Relay output, 10A-AC This output provides energy to the generatorcontactor. If the generator phases do not haveacceptable voltage or frequency values, thegenerator contactor will be de-energized. Instandard genset applications, in order toprovide extra security, the normally closedcontact of the mains contactor should beserially connected to this output. In ‘no breaktransfer’ or ‘parallel with mains’applications, this output will drive directly thegenerator contactor.2 UGenerator phase Connect the generator phases to these inputs.3 Vinputs, 0-300V-AC The generator phase voltages upper and4 Wlower limits are programmable.5 GENERATOR NEUTRAL Input, 0-300V-AC Neutral terminal for the generator phases.6 <strong>MAINS</strong> NEUTRAL Input, 0-300V-AC Neutral terminal for the mains phases.7 TMains phase inputs, Connect the mains phases to these inputs.8 S0-300V-ACThe mains voltages upper and lower limits are9 Rprogrammable.10 <strong>MAINS</strong> CONTACTOR Relay output, 10A-AC This output provides energy to the mainscontactor. If the mains phases do not haveacceptable voltage or frequency values, themains contactor will be de-energized. Instandard genset applications, in order toprovide extra security, the normally closedcontact of the generator contactor should beserially connected to this output. In ‘no breaktransfer’ or ‘parallel with mains’applications, this output will drive directly themains contactor.<strong>705</strong>-UE.doc - 6 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!