NRPB W-14 25(June 02)HPA-RPD-029 26(August 07)Recommended DRL DAP per exam (Gy.cm 2 ) 36 29Number <strong>of</strong> hospitals 7 38Fluoroscopy time per examination (seconds) 294 243Mean patient range 75 – 85 kg 75 – 85 kgNumber <strong>of</strong> rooms 17 110Number <strong>of</strong> patients 8000 34236Fluoroscopy time range (seconds) 185 to 385 93 to 606Third quartile time (seconds) 337 270Mean DAP (Gy.cm 2 ) 30.4 25.7DAP range (Gy.cm 2 ) 11.8 to 60.7 11.7 to 72.5First quartile DAP (Gy.cm 2 ) 22.3 18.9Third quartile DAP (Gy.cm 2 ) 36.3 29.0Patient age (years) 60(16-97) 62 (16-99)Patient weight (kg) 78(35-172) 79(29-183)Number <strong>of</strong> images per exam Not available 737(6-2200)Table 2 : Summary <strong>of</strong> data used to derive Diagnostic Reference Levels2.4.4 Guidance for high skin dose proceduresAlthough guidance documents 25, 26 do give some data on Coronary angioplasties, strictly speakingDiagnostic Reference Levels do not apply. However there have been studies <strong>of</strong> doses frominterventional cardiac examinations where reference levels have been proposed 27, 28 . Moreemphasis is placed, however, on making interventionists more aware <strong>of</strong> the potential injury fromthese procedures and methods for decreasing their incidence by using dose control strategies 6 .2.5 Measuring Patient Dose - Dose Area Product Meter and Skin dose indicatorThe dose area product (DAP) meter is a measure <strong>of</strong> dose in Gray multiplied by the area irradiated.This gives an indication <strong>of</strong> patient dose that can be used to compare with the same parameter for thesame exam. DAP is an easily available measurement which is commonly used to monitor patientdoses for many routine diagnostic imaging procedures. Some imaging systems calculate the DAPfrom known exposure factors but it is understood that the Siemens Axiom Artis uses an integralionisation chamber to determine the DAP. In addition to this value, the system also gives a value <strong>of</strong>skin entrance dose in mGy. This is calculated at a reference point <strong>of</strong> 60cm from the focal spot. Thisis equivalent to a distance <strong>of</strong> 15cm in front <strong>of</strong> the isocentre which is taken to be the most typical10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!