12.07.2015 Views

13 MB 19th Jul 2013 5995373155 Frigidaire 27 Dryers Gas and ...

13 MB 19th Jul 2013 5995373155 Frigidaire 27 Dryers Gas and ...

13 MB 19th Jul 2013 5995373155 Frigidaire 27 Dryers Gas and ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Note:In the auto regular cycle, the timer motor canrun for 51 minutes. The cycle time can be 51min plus the time current flow is being shuntedby the electronic moisture sensor control.The Heating Circuit:Timer contacts B to A connect line 1 to terminal 1 ofthe fabric selector switch. The fabric selector switchallows the dryer to be set to operate at High temperature,Medium temperature, Low temperature or Air Fluff.In the Air Fluff setting the drum turns but the heaterdoes not operate. Whenever the fabric selector switchis set to either High, Medium or Low, contact 1 is closedto contact 2 <strong>and</strong> line 1 is applied to the contacts of thecontrol thermostat. When the fabric switch is set toeither Medium or Low, power is applied to a small heaterin the control thermostat, <strong>and</strong> the control thermostat isthen cycled by a combination of heat from the thermostatheater <strong>and</strong> heat in the drum. When the fabric selectorswitch is set to Medium, contacts 3 to 5 of theswitch are closed connecting the series circuit formedby a 2400 Ohm resister <strong>and</strong> the windings of the smallheater in the control thermostat to line 2. When thefabric selector switch is set to Low, contacts 4 to 5 ofthe switch are closed connecting the windings of thesmall heater in the control thermostat to line 2. Sincemore current flows through the thermostat heater inthe Low setting, the control thermostat cycles at a lowerdrum temperature than Medium.The control thermostat senses the temperature of theair in the blower housing <strong>and</strong> controls the temperaturein the dryer by opening <strong>and</strong> closing the heater circuit.When the temperature in the drum is below the cycletemperature, the contacts are closed, connecting line1 to the high limit thermostat. The high limit thermostatis a safety device that prevents the dryer from overheatingif the contacts of the control thermostat failclosed. The contacts of the high limit thermostat arenormally closed <strong>and</strong> are set to open at a temperatureabove the cycling temperature of the control thermostat.From the output terminal of the high limit thermostat,line 1 is connected to one side of the element.The other side of the element is connected to line 2through the contacts of the second centrifugal switchin the drive motor. This switch prevents power frombeing applied to the element if the motor is not running.The Cycle Signal Circuit:The cycle signal circuit is made up of the cycle signal(buzzer) <strong>and</strong> signal switch which allows the customerto active <strong>and</strong> deactivate the cycle signal feature. Whencontacts B to C of the timer are closed or contacts B toS of the timer are closed <strong>and</strong> the extra care switch is setto ON, line 1 is connected to one side of the cycle signal.The other side of the cycle signal is connected tothe signal switch. When the signal switch is set to ONthe contacts of the switch are closed connecting thecircuit to terminal H of the timer. A Pulsar cam, locatednext to the cycle signal cam <strong>and</strong> rotating at 12 revolutionsper hour, allows contacts H to X to close for 5seconds +/-3 seconds.PULSAR CAMAuto Dry Knits <strong>and</strong> Delicates Cycle:The auto dry knits <strong>and</strong> delicates cycle operates thesame as the auto dry regular cycle except for the lengthof time the timer motor can run (36 minutes) <strong>and</strong> theextra care feature capability. When the extra care featureis selected, the dryer tumbles an extra 16.5 minutesat the end of the cycle without heat. During the16.5 minutes, the end of cycle signal will sound 5 to 7times.Drive Motor <strong>and</strong> Heating Circuits:The drive motor <strong>and</strong> heat circuits operate the same as inthe regular auto dry cycle.Timed Dry CycleWhen the timed dry cycle is selected a drying time upto 73.5 minutes may be set by turning the timer dial.When the cycle is started, the timer motor runs continuouslyfor the time set <strong>and</strong> at the end of the cyclethe end of cycle signal sounds one or two times.Drive Motor <strong>and</strong> Heating Circuits:DRIVECAMThe drive motor <strong>and</strong> heat circuits operate the same as inthe regular auto dry cycle.42

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!