12.07.2015 Views

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Time InitiatedDefrostDefrost Termination TempDefrostTerminationCut-In<strong>Temperature</strong>Compressor or RefrigerationOFF ON OFF ON OFFON OFF ON OFFCut-OutTimeDRAFT VERSIONControllerPower onTime toFirst DefrostCompressorMinimum OnTimeTime toSubsequent DefrostsThe controller can also be configured with a <strong>Temperature</strong> Initiated Defrost Function to start defrosting if it senses too great a difference between thecontrol temperature <strong>and</strong> the evaporator temperature. <strong>Temperature</strong> Initiated Defrost Time Delay begins counting down if the evaporator temperature is lessthan 32ºF (0ºC) <strong>and</strong> an excessive temperature difference is sensed. Defrost starts if the temperature difference still exists when the delay expires. Thistemperature initiated defrost delay prevents defrost from starting if the air space temperature temporarily increases (e.g. the door is left open). Thetemperature difference <strong>and</strong> delay are both configured.<strong>Temperature</strong> Initiated Defrost Time Delay after Defrost begins counting down when refrigeration starts after defrost. This delay is typically longer than<strong>Temperature</strong> Initiated Defrost Time Delay to prevent another defrost before the sensed temperatures return to normal. When <strong>Temperature</strong> Initiated DefrostTime Delay after Defrost expires, the controller resumes use of <strong>Temperature</strong> Initiated Defrost Time Delay as described above. <strong>Temperature</strong> Initiated DefrostTime Delay after Defrost permits a shorter <strong>Temperature</strong> Initiated Defrost Time Delay without the risk of starting defrost due to a lagging control temperatureafter defrost.<strong>Temperature</strong> initiated defrost is independent of time initiated defrost <strong>and</strong> can start before the Time to subsequent defrosts timer expires.<strong>Temperature</strong>Initiated DefrostDefrost Termination TempDefrost TerminationControl Minus EvaporatorStarts Defrost DelayCut-InCut-Out<strong>Temperature</strong>ControlSensorEvaporatorSensorTimeDefrost DelayDefrost StartDefrost DelayAfter Defrost(Defrost Prohibited)Type E7 <strong>Eco</strong><strong>Cool</strong> Electronic <strong>Temperature</strong> <strong>and</strong> Defrost Controllers©2008 Invensys Controls All rights reserved.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!