12.07.2015 Views

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Parameter listThe Parameter List Table includes the default value, range, <strong>and</strong> resolution of all parameters that can be set using the <strong>Eco</strong>Soft Program.DRAFT VERSIONCase name, location or ID: ____________________________________________________________________Configuration name (e.g. Ice Cream.prm): __________________________________________________________Tab Ref Parameter Description Default Min Max ResolutionConfigurationValue1Controller Operation<strong>Temperature</strong> UnitsFahrenheit°C (Celsius) or °F (Fahrenheit)2 Defrost Method Electric Electric, Off Cycle, or Reverse Cycle3Evaporator <strong>Temperature</strong>SensorEnabledEnabled or DisabledConfiguration4Defrost TerminationMethodEvaporatorSensorDisable, Evaporator Sensor, Control Sensor or Switch(NO)5 On/Off function Enabled Enabled or Disabled67Potentiometer Off Position(Degrees)Potentiometer On Position(Degrees)10º 5º 57º 1º15º 9º 61º 1º8 Cut-in warm-10ºC(14°F)-40ºC(-40ºF)40ºC(104ºF)0.5ºC(1°F)Setpoints9 Cut-out warm10 Cut-in cold-20ºC(-4°F)-19ºC(-2°F)-40ºC(-40ºF)-40ºC(-40ºF)40ºC(104ºF)40ºC(104ºF)0.5ºC(1°F)0.5ºC(1°F)11 Cut-out cold-26ºC(-15°F)-40ºC(-40ºF)40ºC(104ºF)0.5ºC(1°F)12Compressor MinimumOff Time at Start Up0 min0 sec0 min0 sec59 min59 sec1 secCompressor13Compressor MinimumOn Time1 min0 min0 sec5 min59 sec1 sec14Compressor MinimumOff Time2 min 0 min59 min59 sec1 secDisplay15Defrost Display Lock(display indication duringdefrost)LOCK Display atTemp. Readingprior to DefrostDisplay the current TEMP read by control sensor, LOCKthe display on the temperature value read by controlsensor when defrost starts <strong>and</strong> until the Cut-Out value isreached, or Display the characters dF during defrost <strong>and</strong>until the Cut-Out value is reached16Display Unlock Time(hh:mm)0 hrs0 min0 hrs0 min1 hr59 min17Display <strong>Temperature</strong>Offset0-40ºC(-40 ºF)40ºC(104ºF)FanNOTE: AllFan Taboptions aredisabledunlessDefrostFunction isdisabled.18Evaporator Fan Operationduring Compressoroff-cycleType E7 <strong>Eco</strong><strong>Cool</strong> Electronic <strong>Temperature</strong> <strong>and</strong> Defrost Controllers©2008 Invensys Controls All rights reserved.EnabledEnabled or Disabled. Although enabled by default, allFan Tab options are disabled unless Defrost Functionis disabled.19 Fan Delay Method Time <strong>Temperature</strong>, Time, or Both20Fan Start Evaporator<strong>Temperature</strong>5ºC(41°F)21 Fan Start Time Delay 1 min22Fan Shut down TimeDelay-40ºC(-40ºF)0 min0 sec0 min 0 min40ºC(104ºF)9 min59 sec9 min59 sec0.5ºC(1°F)1 sec1 sec28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!