12.07.2015 Views

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

Ranco Eco-Cool E71R/E72R Temperature and ... - icemeister.net

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DRAFT VERSIONLow <strong>Temperature</strong> Alarm – Warm PositionSpecifies the sensed low temperature setpoint that causes an alarm when the adjustment knob is in the warm position. Control sensor temperatures equalto or less than this threshold cause an alarm when the adjustment knob is in the warm position.High <strong>Temperature</strong> Alarm – Cold PositionSpecifies the sensed high temperature setpoint that causes an alarm when the adjustment knob is in the cold position. Control sensor temperatures equal toor greater than this threshold cause an alarm when the adjustment knob is in the cold position.Low <strong>Temperature</strong> Alarm – Cold PositionSpecifies the sensed low temperature setpoint that causes an alarm when the adjustment knob is in the cold position. Control sensor temperatures equal toor less than this threshold cause an alarm when the adjustment knob is in the cold position.If the user selects a control setpoint between the warm <strong>and</strong> cold positions, the alarm thresholds are calculated by the controller as linear interpolations fromthe temperaturealarm setpoints.<strong>Temperature</strong> Alarm DifferentialSpecifies the amount of temperature correction required to cancel a temperature alarm. A high temperature alarm is cancelled when the temperature is lessthan the alarm threshold minus the differential. A low temperature alarm is cancelled when the temperature is greater than the low temperature alarmthreshold plus the differential.<strong>Temperature</strong> Alarm Time DelaySpecifies the minimum time that a sensed control temperature must be beyond a temperature alarm threshold before a temperature alarm occurs.<strong>Temperature</strong> Alarm Disable Time after Start upSpecifies how long temperature alarms are disabled after the controller is powered on.<strong>Temperature</strong> Alarm Delay After DefrostSpecifies the maximum time delay before an alarm is activated when the control temperature is beyond an alarm threshold after defrost is terminated bytime or temperature or after drip time has ended - if used.6.2.5.5 CompressorUse the Compressor tab to set compressor protection delays for the minimum power on <strong>and</strong> power off periods for the compressor. These minimum timeperiods can be used to protect the compressor against short cycling.NOTE: Although the Compressor Minimum Off Time can be set as short as zero seconds, time should be provided to protect the compressor against short-cycling.Type E7 <strong>Eco</strong><strong>Cool</strong> Electronic <strong>Temperature</strong> <strong>and</strong> Defrost Controllers©2008 Invensys Controls All rights reserved.20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!