Experience <strong>and</strong> Competence in Environmental EngineeringAmple References<strong>Hitachi</strong> <strong>Power</strong> Europe GmbH (HPE) has both intelligent <strong>and</strong> environmentally compatibleair quality control systems. Our staff insert air quality control systems downstreamof fossil-fired power plants either as an overall concept or as single components(desulphurization, de-nitrification, dust collection). Their extent can be individuallyadapted depending on preference <strong>and</strong> requirement. Our references attest to the fact thatHPE not only fulfills customer preferences but also repeatedly sets raised st<strong>and</strong>ards forthe environment.Project Customer Product Capacity Fuel CommissioningFlue gas rateElectrical powerPrecipitation rateChvaletice 1, 2, 3, 4 2,066,400 Nm³/h 1997Czech RepublicCEZ a.s.FGD200 x 4 MWel95% Lignite1998VresovaCzech RepublicKrabi 1Thail<strong>and</strong>Kozienice #9, 10Pol<strong>and</strong>Kozienice 4–8Pol<strong>and</strong>Sioux 1, 2USACoffeen 1, 2USADuck Creek 1USASokolovskáuhelná a.s.EGATKozienice S.A.Kozienice S.A.AmerenAmerenAmerenFGD 1,510,000 Nm³/h 87% Lignite 2002FGDFGDFGDFGDFGDFGD1,004,000 Nm³/h300 MWel2,066,400 Nm³/h500 MWel3,480,000 Nm³/h(200 x 4 MWel equiv.)2,005,367 Nm³/h2 x 535 MWel1,464,395 Nm³/h2 x 360 MWel1,627,239 Nm³/h444 MWelAbono 2 Hidroelectrica 2,225,780 Nm³/hSpaindel Cantabrico S.A.FGD556 MWelSoto 3 Hidroelectrica 1,330,576 Nm³/hSpaindel Cantabrico S.A.FGD350 MWelLa Robla 2 Unión Fenosa 1,500,000 Nm³/hSpainGeneración S.A.FGD350 MWel90% Oil 200494.8% Coal 200594% Coal 200799% Coal 200899% Coal 200999% Coal 200890% Coal 200890% Coal 200895% Coal 2008Sines 1, 2, 3, 4 1,160,000 Nm³/h 2008PortugalCPPE/EDPFGD4 x 314 MWel90% Coal2009Narcea 3 Unión Fenosa 1,500,000 Nm³/hSpainGeneración S.A.FGD350 MWelWalsumGermanyEvonik/EVNFGD1,800,000 Nm³/h790 MWel95% Coal 200998% Coal 2013Westfalen 1,900,000 Nm³/h 2013/2014GermanyRWEFGD2 x 820 MWel98% Coal(Scheduled)Wilhelmshaven Electrabel/ 1,800,000 Nm³/h 2014GermanyGDF SuezFGD790 MWel99% Coal(Scheduled)Eemshaven 1,900,000 Nm³/h 2014Netherl<strong>and</strong>sRWEFGD2 x 820 MWel98% Coal(Scheduled)Rotterdam Electrabel/ 1,800,000 Nm³/hNetherl<strong>and</strong>sGDF SuezFGD790 MWel99% Coal 2013References of HPE <strong>and</strong> <strong>Hitachi</strong> <strong>Power</strong> Group, as of: June 20134
Constant RefinementsIn keeping with the requirements placed on the environment, the technology of the airquality control systems is constantly refined. The trend in requirements put on air qualitycontrol systems is reflected in the development of emission st<strong>and</strong>ards in Europe.Status of emission st<strong>and</strong>ards in Europe400350Emission st<strong>and</strong>ard300250200150100500SO x(mg/Nm³)NO x(mg/Nm³)Dust(/10 mg/Nm³)HCI(/10 mg/Nm³)HF(/100 mg/Nm³)400 200 30 – –200 200* 20 10 (17th. BImSchV) 1 (17th. BImSchV)100 80 10 8 1■ EU St<strong>and</strong>ard■ 13th. BImSchV■ Actual St<strong>and</strong>ard Germany* 100 as a yearly average0.050.0450.04Emission st<strong>and</strong>ard0.0350.030.0250.020.0150.010.0050Hg(mg/Nm³)Cd + Tl(mg/Nm³)Other HM(*10 mg/Nm³)Dioxins <strong>and</strong> Furans(*10 ng/Nm³)0.03 0.05 0.5 0.10.03 0.05 0.5 0.1■ 13th. BImSchV■ Actual St<strong>and</strong>ard Germany<strong>Air</strong> <strong>Quality</strong> <strong>Control</strong> <strong>Systems</strong> 5