12.07.2015 Views

HWS Series - TDK-Lambda

HWS Series - TDK-Lambda

HWS Series - TDK-Lambda

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HWS</strong><strong>Series</strong><strong>HWS</strong>/MEAC/DC Switching power supply formedical applicationEra where standard power supply used in medical applicationLine upP51Medical safety standard (EN60601/UL60601)complianceContribute to shortened the time needed in developingmedical equipment and reduce its cost7 models with 42 line upsMain applicationsMedical lasers,X-Ray,Microwave theraphyequipmentDiagnosis equipments,Analysis/testingdevicesLeakage current: max. 0.5mAEMC Immunity (All models)ItemsElectrostaticRadiated susceptibilityElectrical fast transient/burstSurgeConducted susceptibilityPower frequency magnetic fieldVoltage dips. Short interuptionStandardlEC61000-4-2lEC61000-4-3lEC61000-4-4lEC61000-4-5lEC61000-4-6lEC61000-4-8lEC61000-4-11Compliance LevelLevel3(Level 2,3 for300W, 600W)Level 3Level 3Level 3,4Level 3Level 4CompliedNotesAerial discharge: 8kVContact discharge:6kV(4kV for 1500W)10V/m2kVCommon: 4.0kVDifferential mode: 2.0kV10V30A/mEmission (<strong>HWS</strong>30,50,100,150,300/ME) Emission (<strong>HWS</strong> 600,1500/ME)Test itemsStandardNotesTest itemsStandardNotesRadiated electric fieldEN55022/EN55011,FCC,VCCIClass B ComplianceRadiated electric fieldEN55022/EN55011,FCC,VCCIClass A ComplianceConducted emissionsEN55022/EN55011,FCC,VCCIClass B ComplianceConducted emissionsEN55022/EN55011,FCC,VCCIClass A ComplianceConducted harmonicsIEC61000-3-2ConformedConducted harmonicsIEC61000-3-2ConformedFlickerIEC61000-3-3ConformedFlickerIEC61000-3-3ConformedAttention:Please read the instruction manual carefully before using this product. On top of the following condition, please refer to to "<strong>HWS</strong> <strong>Series</strong>" standard instruction manual (p25-).Please confirm whether there is insulation materials used inside the equipment (whether there is patient direct contact or indirect contact with the equipment). All models areapproved for basic insulation, therefore additional insulation circuit may be needed in the equipment.<strong>HWS</strong>/HDAC/DC Standard switching power supplyfor rugged and heavy dutyHarsh environment applicationsLine upP31-40 Start upMain applicationsPCB coatingDesigned to meet MIL-STD-810F(shock and vibration)LED displayDeviceProcesscontrolFactorymachinery

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!