<strong>HWS</strong>100/ME<strong>HWS</strong>100/ME Specifications(Read instruction manual carefully, before using the power supply unit.)<strong>HWS</strong> <strong>HWS</strong> HD <strong>HWS</strong> ME <strong>HWS</strong>-PInstruction ManualITEMS/UNITSMODEL <strong>HWS</strong>100-5/ME <strong>HWS</strong>100-12/ME <strong>HWS</strong>100-15/ME <strong>HWS</strong>100-24/ME <strong>HWS</strong>100-48/MEVoltage Range (*2) V AC85 - 265 or DC120 - 370Frequency (*2) Hz 47 - 63Power Factor (100/200VAC)(typ) (*1) 0.99 / 0.95Input Efficiency (100/200VAC)(typ) (*1) 83 / 86 84 / 87Current (100/200VAC)(typ) (*1) A 1.3 / 0.65Inrush Current (100/200VAC)(typ) (*3) A 14/28 at, Ta=25, cold startLeakage Current (*10) mA Less than 0.5. (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)Nominal Voltage VDC 5 12 15 24 48Maximum Current A 20 8.5 7 4.5 2.1Maximum Power W 100 102 105 108 100.8Maximum Line Regulation (*5) mV 20 48 60 96 192OutputMaximum Load Regulation (*6) mV 40 96 120 192 384Temperature CoefficientLess than 0.02% / Maximum Ripple & Noise (07.35 >4.72 >2.20Over Voltage Protection (*8) VDC 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8Remote SensingPossibleFunctionParallel Operation -<strong>Series</strong> OperationPossibleLine DIPDesigned to meet SEMI-F47 (200VAC Line only)Operating Temperature (*11) -10 to +70 (-10 to +50: 100%, +60: 60%, +70: 20%)Storage Temperature -30 to +85Operating Humidity RH 30 - 90 (No dewdrop)Storage Humidity RH 10 - 95 (No dewdrop)EnvironmentAt no operating, 10 - 55Hz (sweep for 1min)Vibration19.6m/s² constant, X, Y, Z 1hour each.Shock (In package)Less than 196.1m/s²CoolingConvection coolingInput - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)Withstand VoltageIsolation Output - FG : 500VAC (100mA) for 1minIsolation ResistanceMore than 100M at 25 and 70%RH Output - FG : 500VDCSafety Standards (*12) Approved by UL60601-1, EN60601-1, CSA-C22.2 No.601.1-M90PFHCDesigned to meet IEC61000-3-2Voltage Fluctuations / Flicker EmissionsDesigned to meet IEC61000-3-3StandardsEMIDesigned to meet EN55011/EN55022-B, FCC-B, VCCI-BImmunityDesigned to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3),-5(Level 3,4), -6(Level 3), -8(Level 4), -11Weight (typ) g 450MechanicalSize (W x H x D) mm 28 x 82 x 160 (Refer to outline drawing)(*1) At 100/200VAC, Ta=25 and maximum output power.(*2) For cases where conformance to various safety specs (UL, EN, CSA) are required,to be described as 100 - 230VAC (50/60Hz).(*3) Not applicable for the in-rush current to noise filter for less than 0.2ms.(*4) Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.(*5) 85 - 265VAC, constant load.(*6) No load-full load, constant input voltage.(*7) Constant current limit and Hiccup with automatic recovery.Not operate at over load or dead short condition for more than 30 seconds.(*8) OVP circuit will shutdown output, manual reset (re power on).(*9) At 100/200VAC, nominal output voltage and maximum output current.(*10) Measured by the each measuring method of UL, EN and CSA (at 60Hz).When using it as a patient care equipment, all outer surfaces of the equipment shall be constructed ofnonconductive material. See clause 19.5DV.2 of UL60601-1.(*11) Ratings - Derating at standard mounting.- Load (%) is percent of maximum output power or maximum output current, whichever is greater.- As for other mountings, refer to derating curve.(*12) As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90, basic insulation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!