A110. Wiring Diagrams! WARNINGRisk of electric shocks. Before performing any maintenance or servicing, always disconnect theunit from its power source. This product employs overload protection (fuse). A blown fuse indicatesan overload or short-circuit situation. If the fuse blows, unplug the product from the outlet.Replace the fuse as per the servicing instructions (follow product marking for proper fuse rating)<strong>and</strong> check the product. If the replacement fuse blows, a short-circuit may be present <strong>and</strong> the productshould be discarded or returned to an authorized service facility for examination <strong>and</strong>/or repair.ConnectionModels: SOLO 1.5 <strong>and</strong> 2.0NEUTRALJ1 2120V 60HzBKGRYRBKFROM MAINNOTES 1, 5S1LogicWALL CONTROLWALL CONTROLWALL CONTROLWALL CONTROLM1J1 1FANMOTORMEDNCHIGHLOWJ1 6NOTE 5OPTIONALOVERRIDE SWITCHOVERRIDE SWITCHOVERRIDE LEDYJ1 3J1 4NOTES 5, 6OPTIONALFURNACE BLOWERINTERLOCKCOLOR CODEBK BLACK NC NO CONNECTIONBL BLUE O ORANGEBN BROWN R REDG GREEN W WHITEGY GREY Y YELLOWM2K2RELAYK1RELAYJ1 9NOTE 4J1 8DAMPERMOTORK5RELAYA1J3 1FURNACE BLOWER INTERLOCKCLASS 2 CIRCUIT ONLYK4RELAYJ3 2ELECTRONIC ASSEMBLYJU121ABCDEFG4 5 6 7 8 9DEFROSTTEMPERATURESENSORJ4VE0018AFF IOCOLY RGB1 2 3R1M1NEUTRALHIGHLOWMEDIUMFAN MOTORT1X1GYOGRBLJ3GY 12OG3NCBNC1BNGYJU 1DEFROST TIMEJUMPERS TABLE MO 21DEFROST/VENTILATIONA B C D E F GTYPE MINUTES23°F 5°F -22°FJU1A JU1B JU1C JU1D JU1E JU1F JU1G -5°C -15°C -27°CIN OUT OUT OUT IN IN OUTSTANDARD MODE43720, <strong>45720</strong>,43725, <strong>45725</strong>6/60 6/32 6/20IN OUT OUT OUT IN OUT OUTEXTENDED DEFROSTSTANDARD MODE10/30 10/20 10/15OUT IN IN IN IN IN OUTSPECIAL MODE43720, <strong>45720</strong>,43725, <strong>45725</strong>6/60 6/32 6/20OUT IN IN IN IN OUT OUTEXTENDED DEFROSTSPECIAL MODE10/30 10/20 10/15. .RR(NOTE 2)741J12BL3BL96X2 M2OBKWELECTRONIC ASSEMBLYBLBLG DAMPER MOTOR12BLBL233GGLINE VOLTAGEMAIN EARTHINGPOINTLOW VOLTAGE ANDFIELD WIREW1GW120VNOCOMBKNEUTRALLINE F1NOTE 7BKFUNCTION TABLE RELAYMODE K1 K2 K4* K5Intermittent 0 0 0 1Exchange Low 1 0 1 0Exchange High 1 1 1 0Circulation Low 1 0 1 1Circulation High 1 1 1 1Defrost Cycle 1 1 1 1Off 0 0 0 1NEMA-15P5-15 PLUGDOOR INTERLOCKSWITCH S1VE0017ANOTES1- Controls available. See Section 8.0 (Low voltage only, 12VDC)2- The factory set wiring for blower speed selection is high <strong>and</strong> low. Medium speedcan be selected instead of low speed. Disconnect the RED wire from the motorRED tap <strong>and</strong> connect it to the motor BLUE tap.3- If any of the original wire, as supplied, must be replaced, use the same orequivalent wire.0 = Relay coil is de-energized1 = Relay coil is energized* On special mode, K4 is cycling 10 min. ON <strong>and</strong> 20 min. OFF4- Use the factory supplied protective tubing.5- The field wiring must comply with applicable codes, ordinances <strong>and</strong> regulations.6- The furnace fan circuit must be class 2 circuit only.7- SPECIFIED UL LISTED/CSA CERTIFIED LINE FUSE.LittelFuse (225 003), 2AG Fast-Acting Fuse. 224/225 Series, Rating: 3A.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!