12.07.2015 Views

Visualiner Series - Snap-on Equipment

Visualiner Series - Snap-on Equipment

Visualiner Series - Snap-on Equipment

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

C<strong>on</strong>soleAligner Comp<strong>on</strong>entsThe c<strong>on</strong>sole houses many of the aligner comp<strong>on</strong>entsincluding the power supplies, the computer system,the head interface comp<strong>on</strong>ents, and provides placesfor the display m<strong>on</strong>itor, keyboard, and printer. Themeasuring heads are placed <strong>on</strong> the sides of the lowercabinet when not in use.The upper porti<strong>on</strong> of the c<strong>on</strong>sole provides a locati<strong>on</strong>for the display m<strong>on</strong>itor, computer system, and keyboard.The m<strong>on</strong>itor has no external adjustments. Thecomputer system is housed to the right side of them<strong>on</strong>itor. The fr<strong>on</strong>t of the computer is accessed by adoor that swings up and can be slid back. Thecomputer has a fr<strong>on</strong>t-mounted power switch thatc<strong>on</strong>trols power to the entire system. The computeralso c<strong>on</strong>tains a CD-ROM drive where the operatingsoftware is loaded, plus a floppy drive used for futureuse.The lower part of the c<strong>on</strong>sole has a printer drawer tokeep the printer away from shop elements. Thedrawer is mounted <strong>on</strong> a slide mechanism to easeusage and paper replacement. The storage cabinetis used to store extra fanfold computer paper, and hasother pockets for storing additi<strong>on</strong>al items.NOTE: Be careful not to expose the aligner ormeasuring heads to water, heavy dust envir<strong>on</strong>ments,or operati<strong>on</strong>s that produce metal chips.Do not block the rear of the computer or disablethe cooling fan.The main On/Off switch for the aligner is locatedbehind the computer access door <strong>on</strong> the fr<strong>on</strong>t of thealigner. The main power cable c<strong>on</strong>nects to the rear ofthe unit. Next to the plug are a series of protectivefuses. In the event of a power overload, <strong>on</strong>e or moreof these fuses may blow, rendering the aligner unusable.Check the fuses whenever the unit is n<strong>on</strong>operati<strong>on</strong>al.The head interc<strong>on</strong>nect cables plug into the back ofthe c<strong>on</strong>sole. There are 6 female c<strong>on</strong>nectors -- <strong>on</strong>e foreach of the 4 heads, <strong>on</strong>e for the opti<strong>on</strong>al remotedisplay unit, and <strong>on</strong>e spare. When the aligner isutilized with a rack wiring kit, all 6 c<strong>on</strong>nectors areused. The c<strong>on</strong>nectors are universal -- it does notmatter which head is plugged into any of the 6c<strong>on</strong>nectors.M<strong>on</strong>itorOn/Off SwitchCD/FloppyDrive AccessKeyboardRemoteC<strong>on</strong>trollerPrinter DrawerLower CabinetPaper StorageFigure 2. <str<strong>on</strong>g>Visualiner</str<strong>on</strong>g> Fr<strong>on</strong>t ViewPage 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!