8 | Getinge POKA-YOKE AERLOAD, START AND UNLOADWITHOUT TOUCHINGInfection control is about seeing the whole picture, and as far as possible, ensuring the risk of human errorsis eliminated.For example: avoiding the situation where a nurse <strong>to</strong>uches a handle, panel, start-but<strong>to</strong>n or barcode readerafter holding a dirty endoscope, leaving micro-organisms waiting <strong>to</strong> be picked up when unloading the cleanendoscope?The answer is: <strong>to</strong>uch-free operation.The first part is basic: a foot pedalAfter the manual pre-cleaning, the opera<strong>to</strong>r presses the pedal <strong>to</strong>open the AER. No need <strong>to</strong> <strong>to</strong>uch any handles or but<strong>to</strong>ns.After successful decontamination the door can only be opened withthe pedal on the clean side.Then, the best part: RFID identification and au<strong>to</strong>matic startWhen the opera<strong>to</strong>r has placed the endoscope in<strong>to</strong> the AER, its RFIDtag is au<strong>to</strong>matically identified by the machine’s RFID antenna (RFID =Radio-Frequency Identification). The opera<strong>to</strong>r also has a RFID tag forau<strong>to</strong>matic user identification.When the foot pedal is pressed, the Getinge POKA-YOKE will close thelid and au<strong>to</strong>matically starts endoscope <strong>reprocess</strong>ing.Smooth, simple and failsafeThis procedure has several benefits. Firstly, it is easy and savestime for the opera<strong>to</strong>r. No data <strong>to</strong> be entered, just load the endoscopeand press the pedal.Secondly, it reduces the risk of human errors. Only the correct cyclefor that particular endoscope can be used. The AER cannot be startedor unloaded without s<strong>to</strong>ring the correct user information.Thirdly, it reduces the risk of cross-contamination. No but<strong>to</strong>ns <strong>to</strong><strong>to</strong>uch <strong>to</strong> open or close the lid, select a cycle, enter user information, startthe AER or unload the clean endoscope.It couldn’t be simpler – or <strong>safer</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!