01.12.2012 Views

Understanding the Software Options

Understanding the Software Options

Understanding the Software Options

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

and also for more intensive deagglomeration.<br />

In order to exclude undesired<br />

side reactions and ensure a consistent<br />

quality level, <strong>the</strong> process takes place in<br />

a fine vacuum (0.133 mbar). The reactor<br />

supplies a constantly high mixing<br />

quality with fill levels from 10 to 100%.<br />

A very high degree of residue emptying<br />

is achieved when changing products<br />

thanks to <strong>the</strong> patented SimConvex<br />

mixing tool (photo, p. 20I-4), which<br />

has an outer contour with a sinusoidal<br />

shape. The mixing device is driven<br />

from above and is fully heatable. The<br />

shaft seals of <strong>the</strong> mixer shaft and <strong>the</strong><br />

cutting rotor are face seals, and <strong>the</strong><br />

sealing valve at <strong>the</strong> end of <strong>the</strong> mixing<br />

cone, which works without dead space,<br />

is gas tight. The mixing chamber is<br />

made of Hastelloy C22. — amixon<br />

GmbH, Paderborn, Germany<br />

www.amixon.com<br />

No contact required<br />

for this flowmeter<br />

LiquiSonic (photo, p. 20I-6) consists of<br />

one or more sensors and a controller.<br />

The contactless measuring method is<br />

based on <strong>the</strong> sonic velocity measurement<br />

for a precise and fast data acquisition.<br />

The sensor is made of stainless<br />

steel, but can be coated with Halar,<br />

PFA or Tantalum to handle aggressive<br />

liquids. The completely enclosed design<br />

of <strong>the</strong> sensor eliminates <strong>the</strong> need for<br />

gaskets or “windows” to <strong>the</strong> process,<br />

and <strong>the</strong>refore works maintenance-free.<br />

The sensor is available with an Ex approval<br />

for using in hazardous areas.<br />

Up to four sensors can be connected<br />

to one controller. — SensoTech GmbH,<br />

Magdeburg-Barleben, Germany<br />

www.sensotech.com<br />

GEA Ecoflex<br />

Eliminate downtime with a<br />

skid-mounted pair of PHEs<br />

The GEASkid version of <strong>the</strong><br />

NT NT Series (photo) is a plate<br />

heat exchanger (PHE) mod<br />

ule with permanent standby<br />

function, comprising two<br />

completely independent<br />

PHEs designed to elimi<br />

nate machine downtimes<br />

caused by maintenance. The<br />

GEASkid was de- de<br />

veloped to meet <strong>the</strong><br />

safety requirements<br />

in power stations, and<br />

is especially suited to cooling<br />

lubricating oil. The module is fitted<br />

with two identical high-performance,<br />

gasketed PHEs that are installed in<br />

a space saving way on a single frame.<br />

The space requirements are considerably<br />

reduced compared to shelland-tube<br />

heat exchangers, says <strong>the</strong><br />

manufacturer. Only a single unit is<br />

required to provide reliable turbine<br />

cooling; if one PHE fails or requires<br />

servicing, operators can immediately<br />

switch over to <strong>the</strong> stand-by PHE<br />

without having to interrupt <strong>the</strong> cooling<br />

cycle — GEA PHE Systems, GEA<br />

Ecoflex GmbH, Sarstedt, Germany<br />

www.gea-ecoflex.de<br />

Avoid product loses and fugitive<br />

emissions with this AE unit<br />

The Midas Meter is <strong>the</strong> next generation<br />

in acoustic-emissions (AE) valve<br />

leak detection equipment from this<br />

company. The system detects leaks<br />

long before detection by conventional<br />

methods or instrumentation, claims<br />

<strong>the</strong> manufacturer. The device has approval<br />

for, among o<strong>the</strong>rs, ATEX 11 1<br />

G Ex ia IIC T4 Ga and IECEX Ex ia<br />

IIC T4 Ga (Ta = –20 to 50°C). — Score<br />

Group Plc., Aberddeenshire, U.K.<br />

www.midasmeter.com<br />

These remote I/O systems are<br />

now more compact<br />

LB/FB Remote I/O Systems are used to<br />

connect intrinsically safe Namur switching<br />

signals and solenoid valve outputs<br />

as well as temperature inputs, or <strong>the</strong><br />

supply of two- or four-wire transmitters,<br />

proportional valves and positioners.<br />

LB Remote I/O is installed in <strong>the</strong> safe<br />

area or Zone 2 Div. 1, while <strong>the</strong> encapsulated<br />

FB Remote I/O can be installed<br />

Circle 4 on p. 54 or go to adlinks.che.com/35068-04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!