14.0 COLD INSULATION:-A) Insulation materials slabs and sections shall be stored on a flatsurface in horizontal position. All precautions shall be taken to ensurethat each day's work is vapour sealed and cladded during erection andbe<strong>for</strong>e being left over-night to prevent seepage of water into thematerials and getting trapped. The system shall be protected bytarpaulins, water shed and other protective means.B) All flanged joints shall be cold insulated with removable boxinsulation. Bonnet of valves above the packing gland does not requireinsulation.C) All materials used <strong>for</strong> insulation, fixing, sealing, and protection shallbe new and shall con<strong>for</strong>m to the specifications. All insulatingmaterials whether dry or wet shall be non-corrosive to the surfacesinsulated.D) Operating Temperature Range: Insulation Materials:- 195 0 C to + 80 0 C Polyurethane foam or PolystyreneE) Form of Insulation <strong>for</strong> Pipes upto 16" dia : Pre<strong>for</strong>med pipes sections.The material used shall not disintegrate, settle, and change its <strong>for</strong>m ofcomposition, in a detrimental way at the service conditions. Thematerial shall be chemically inert, moisture free rot and vermin proof.F) Polyurethane foam:a) The insulation material shall be rigid pre <strong>for</strong>med cellular Urethanefoam of self-extinguishing type in accordance with ASTM-C - 591,TYPE - II Grade - 2. The foam shall be <strong>for</strong>mulated in such a way thatit shall be of a self-extinguishing quality which under nocircumstances shall cause fire to spread.b) The density of finished foam shall be within 35.0 Kg/m 3 Kg/M3 to 40Kg/m 3 and shall be determined in accordance with ASTM C-302.c) Thermal conductivity: Thermal conductivity of the polyurethane foamslabs and sections shall not be exceed 0.019 K Cal/hr. M C (0.16BTU/ft2 hr F /inch.) at 10 C mean temperature after ageing.G) Pipe support Finished foam PUF density will be 250 Kg/m 3 and shallbe determined in accordance with ASTM C-302.H) ANCILLARY MATERIALS:a) Wire netting shall be galvanized 22 SWG x 20 MM to secure insulationblocks. Lacing and stitching wires shall be 22 SWG galvanized ironwireb) Bands: Shall be of Aluminum, of dimension 20 mm width x 22 SWG,unless specified otherwise.25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!