ENCLOSEDENERGYMANAGEMENTEQUIPMENTEXTENSIONMODULERS-485EXTENSIONMODULERS-485 connected to A and the higher stage of the same boiler must be connected to Stage B. The boilervalve or pump for the same boiler must be connected to Stage C.N Stage A Stage B Stage C Stage D Stage E Stage F2 3 4 5 6 7 8 9 10 11 12 13 14LNLo HiUnit1StagesUnit1PumpLo HiUnit2StagesUnit2Pump connect to the second extension or the 420MOD Interface. communication problem. (Switch is set to "B") will operate stages "Q" through "X".Connecting <strong>BCP</strong>-8 to Two Extension Panelsand 420MOD Interface using RS485Ext AExt B<strong>BCP</strong>-8<strong>BCP</strong>-8X A<strong>BCP</strong>-8WHYDRONIC SEQUENCING CONTROL<strong>BCP</strong>-8XSEQUENCING CONTROL EXTENSIONStage AStage BStage CStage DStage EStage FStage GStage HSYS=144F OD=35FSYSTEMDHW PUMP DE GH JKHI LO -- OFFCOMB. AIRSTAGE MENUI QJ RK SL TM UN VCommO WP XPowerOUTPUT RATINGS:120VAC, 6A RESISTIVE1A PILOT DUTY, 15A TOTALFOR ALL CIRCUITSINPUT RATINGS:115VAC 60Hz, 12VA MAXINPUT RATINGS:115VAC 60Hz, 12VA MAXLISTED99RACUSPWRL N1 2DO NOT APPLY ANY VOLTAGE TO INPUT TERMINALSCAUTION: Risk of Electric Shock.SENSORS MUST BE GOLD SERIESUse Copper Conductors Only.PROGRAM RUNDHW COMB.SHUTDOWNRS485Stage A Stage B Stage C Stage D Stage E Stage F Stage G Stage H SYSTEMPRESSOUTDOOR RETURNPUMPDHW /TSTATAIRTEMPPROVE+ -TEMP TEMP/SETBACK3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38PWRL N1 2CAUTION: Risk of Electric Shock.Use Copper Conductors Only.Ext AI Q J R K S L T M U N V O W P X3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18Ext B6 Pin Phone Cable (provided with Extension)<strong>BCP</strong>-8X B<strong>BCP</strong>-8XSEQUENCING CONTROL EXTENSION420MOD EMS InterfaceI QJ RK SL TM UN VCommO WP XPowerOUTPUT RATINGS:120VAC, 6A RESISTIVE1A PILOT DUTY, 15A TOTALFOR ALL CIRCUITSINPUT RATINGS:115VAC 60Hz, 12VA MAX4-20 mA EMS4-20mA INPUTRS485+ Signal GNDEXTENSION1 2 3CONNECTORSPWRCAUTION: Risk of Electric Shock.Use Copper Conductors Only.I Q J R K S L T M U N V O W P XExt AExt BL N1 23 4 5 6 7 8 9 10 11 12 13 14 15 16 17 184-20mA (+)EMS Signal (-)6 Pin Phone Cable (provided with 420MOD EMS Interface)13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!