12.07.2015 Views

London Fire Safety Guidance for Houses in ... - Harrow Council

London Fire Safety Guidance for Houses in ... - Harrow Council

London Fire Safety Guidance for Houses in ... - Harrow Council

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Houses</strong> Converted to Self-Conta<strong>in</strong>ed Flats(Includ<strong>in</strong>g Studio Flats), each Occupied by aS<strong>in</strong>gle HouseholdONE OR TWO STOREY HOUSE CONVERTED TO SELF-CONTAINED FLATS, EACH OF WHICH IS OCCUPIED BY ASINGLE HOUSEHOLDThese are HMOs where no floor level exceed<strong>in</strong>g 4.5m <strong>in</strong> height above groundand no floor greater than 200 m 2 <strong>in</strong> areaGrade D System• Ma<strong>in</strong>s wired smoke alarms with battery back-up• L<strong>in</strong>ked so that all sound when any one alarm is activated• May be wired to the local light<strong>in</strong>g circuit or alternatively to.a s<strong>in</strong>gle<strong>in</strong>dependent circuit at the dwell<strong>in</strong>g’s (i.e. house’s) ma<strong>in</strong> distributionboard – no other equipment to be connected to this circuit other than acircuit monitor<strong>in</strong>g device.LD2 Category Coverage• Interl<strong>in</strong>ked smoke alarms sited <strong>in</strong> staircase enclosure, land<strong>in</strong>gs andhallways and lobbies <strong>in</strong>clud<strong>in</strong>g <strong>in</strong>ternal hallway/lobby of each flat nearbut not outside the kitchen (false alarms).• Kitchen, bedrooms and liv<strong>in</strong>g rooms not covered by smoke alarms.• If no <strong>in</strong>ternal hallway/lobby is provided smoke or heat alarms shall besited <strong>in</strong> the room(s) adjo<strong>in</strong><strong>in</strong>g the staircase. Where cook<strong>in</strong>g facilities areprovided they shall be heat alarms. In bedsits conta<strong>in</strong><strong>in</strong>g cook<strong>in</strong>gfacilities, <strong>in</strong> addition to the heat alarm, a non-<strong>in</strong>terl<strong>in</strong>ked smoke alarm,with battery back-up, wired to the local light<strong>in</strong>g circuit and to sound only<strong>in</strong> the room concerned shall be provided.THREE, FOUR, FIVE OR SIX STOREY HOUSE CONVERTED TOSELF-CONTAINED FLATS, EACH OF WHICH IS OCCUPIED BYA SINGLE HOUSEHOLDThese are those HMOs where one or more level exceeds 4.5m above groundand/or any floor is greater than 200 m 2 <strong>in</strong> areaGrade A System <strong>Fire</strong> detection and alarm system designed and <strong>in</strong>stalled <strong>in</strong>accordance with BS 5839: Part 1, except clauses relat<strong>in</strong>g to alarmaudibility, alarm warn<strong>in</strong>gs <strong>for</strong> the hear<strong>in</strong>g impaired, manual callpo<strong>in</strong>ts, capacity of standby batteries, (and radio-l<strong>in</strong>ked systems)which are amended by BS 5839: Part 6. Control panel to standard of BS EN 54-2 (power supply to BS EN54-4).<strong>London</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Houses</strong> <strong>in</strong> Multiple OccupationVersion 2: 06/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!