Ma<strong>in</strong>s wired smoke alarms with battery back-up L<strong>in</strong>ked with<strong>in</strong> the FMO so that all sound with<strong>in</strong> the FMO when anyone alarm is activated May be wired to the local light<strong>in</strong>g circuit, or alternatively to a s<strong>in</strong>gle<strong>in</strong>dependent circuit at the dwell<strong>in</strong>g’s (i.e. flat’s) ma<strong>in</strong> distributionboard – no other equipment to be connected to this circuit other thana circuit other than a circuit monitor<strong>in</strong>g device.LD2 Category Coverage Interl<strong>in</strong>ked smoke alarms sited <strong>in</strong> <strong>in</strong>ternal hallway/lobby of each flat. Interl<strong>in</strong>ked smoke alarms sited <strong>in</strong> bedrooms and liv<strong>in</strong>g rooms Inter<strong>in</strong>ked heat alarms sited <strong>in</strong> kitchens. Any bedroom with cook<strong>in</strong>gfacilities should be treated as a bedsit.AN FMO WITHIN A PURPOSE-BUILT BLOCK OF FLATS (MANSIONBLOCK)Grade D System Ma<strong>in</strong>s wired smoke alarms with battery back up. L<strong>in</strong>ked so that all sound when any one alarm is activated. May be wired to the local light<strong>in</strong>g circuit, or alternatively, to a s<strong>in</strong>gle<strong>in</strong>dependent circuit at the dwell<strong>in</strong>g’s (i.e. flat’s) ma<strong>in</strong> distributionboard – no other equipment to be connected to this circuit other thana circuit monitor<strong>in</strong>g device.LD2 Category CoverageInterl<strong>in</strong>ked smoke alarms sited <strong>in</strong> <strong>in</strong>ternal hallway/lobby of flat.Interl<strong>in</strong>ked smoke alarms bedrooms and liv<strong>in</strong>g roomsInterl<strong>in</strong>ked heat alarms <strong>in</strong> kitchensGENERAL POINTS APPLICABLE TO ALL SYSTEMSSilenc<strong>in</strong>g and disablement facilitiesIn order to avoid the use of undesirable methods of disablement, all firedetection and alarm systems with<strong>in</strong> the scope of these parts of BS 5839should be provided with suitable and readily accessible means by which theuser can silence fire alarm signals without the use of a tool. If access to ceil<strong>in</strong>gmounted smoke alarms is difficult this may justify upgrad<strong>in</strong>g the system to oneprovid<strong>in</strong>g an element of central control.User responsibilities test<strong>in</strong>g and servic<strong>in</strong>gThe recommendations of the appropriate parts should be followed.<strong>London</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Houses</strong> <strong>in</strong> Multiple OccupationVersion 2: 06/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!