Recommended maximum travel distances with<strong>in</strong> a unit ofaccommodationHabitable rooms – from any po<strong>in</strong>t with<strong>in</strong> the room to the room exit: 9.0 metres.From any exit from a room to the entrance door of the accommodation unit : 9.0metres.From the entrance door of the accommodation to the nearest stairway: 7.5metres.Stage 2 : Travel from the entrance door of a unit of accommodation to af<strong>in</strong>al exitAn unlimited travel distance <strong>in</strong> stage 2 will be acceptable if it is <strong>in</strong> aprotected route.Where the travel is not entirely with<strong>in</strong> a protected route the follow<strong>in</strong>g shallapply:The factors which have to be considered when assess<strong>in</strong>g means of escapewill vary from one situation to another. Accord<strong>in</strong>gly, <strong>for</strong> reasons similar tothose stated above, the distances suggested <strong>in</strong> the follow<strong>in</strong>g paragraphsshould be regarded as guidel<strong>in</strong>es and not as hard and fast limits.<strong>London</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Houses</strong> <strong>in</strong> Multiple OccupationVersion 2: 06/06