Material/ProductA Brickwork, blockwork, concrete,plasterboard (all types), plasterf<strong>in</strong>ishes (<strong>in</strong>clud<strong>in</strong>g render on wood ormetal laths) andAny other product with Class 0classification and valid test reportB Timber, hardboard, particleboard(chipboard) andAny other product with Class 3 rat<strong>in</strong>gwith valid test reportC As Group B above but flameretardant treated to Class 1 with validtest certificateD Woodwool slabE Non-flame-retardant decorativelam<strong>in</strong>atesF Flame-retardant decorativelam<strong>in</strong>ates to Class 1 with valid testcertificateG Expanded polystyrene wall andceil<strong>in</strong>g lam<strong>in</strong>ates:• maximum thickness 5mm (walls),12mm (ceil<strong>in</strong>gs), with only one coat ofwater-based emulsion f<strong>in</strong>ish• where pa<strong>in</strong>ted with gloss pa<strong>in</strong>tH Th<strong>in</strong> v<strong>in</strong>yl and paper cover<strong>in</strong>gs on<strong>in</strong>organic (Group A above) surfaceI Heavy flock paper – non-flameretardantgradeJ Heavy flock paper – flame-retardantgrade to Class 1 with valid testcertificateAcceptable locationsAll locations <strong>in</strong>clud<strong>in</strong>g hostelsALL TYPES OF HMO (<strong>in</strong>clud<strong>in</strong>ghostels)Not permitted <strong>in</strong> escape routes, iestairways, hallways, land<strong>in</strong>gs, lobbiesHOSTELS ONLYPermitted <strong>in</strong>:Small rooms not greater than 4 sq mfloor area,Small areas of walls <strong>in</strong> larger rooms(area not greater than half floor areaor 20 sq m, whichever is lesserNot permitted <strong>in</strong> ceil<strong>in</strong>gsHMOs (not hostels)Unrestricted <strong>in</strong> roomsAll locations <strong>in</strong>clud<strong>in</strong>g hostelsAll locations <strong>in</strong>clud<strong>in</strong>g hostelsAs Group B aboveAll locations <strong>in</strong>clud<strong>in</strong>g hostelsAs Group B aboveNot permitted <strong>in</strong> any location, shouldbe removed if exist<strong>in</strong>gAll locations <strong>in</strong>clud<strong>in</strong>g hostelsAs Group B aboveAll locations except hostelsTable 2 - Classifications of rate of spread of flame <strong>for</strong> various productsand acceptable locations <strong>for</strong> their useNote – Class 1 can sometimes be achieved by the application of proprietaryproducts. It is imperative to obta<strong>in</strong> a valid test report <strong>for</strong> the product <strong>in</strong> an<strong>London</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Houses</strong> <strong>in</strong> Multiple OccupationVersion 2: 06/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!