12.07.2015 Views

London Fire Safety Guidance for Houses in ... - Harrow Council

London Fire Safety Guidance for Houses in ... - Harrow Council

London Fire Safety Guidance for Houses in ... - Harrow Council

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Bedsit -Type <strong>Houses</strong> <strong>in</strong> Multiple OccupationONE OR TWO STOREY HOUSE WHICH PROVIDES BEDSIT-TYPE ACCOMMODATIONi.e. no floor level exceed<strong>in</strong>g 4.5m <strong>in</strong> height above ground and/or no floorgreater than 200 m 2 <strong>in</strong> areaGrade D System Ma<strong>in</strong>s wired smoke alarms (heat alarms if bedsit conta<strong>in</strong>s cook<strong>in</strong>gfacilities) with battery back-up L<strong>in</strong>ked so that all sound when any one alarm is activated May be wired to the local light<strong>in</strong>g circuit, or alternatively to a s<strong>in</strong>gle<strong>in</strong>dependent circuit at the dwell<strong>in</strong>g’s (i.e. house’s) ma<strong>in</strong> distributionboard – no other equipment to be connected to this circuit other thana circuit monitor<strong>in</strong>g device.LD2 Category Coverage Smoke alarms (<strong>in</strong>terl<strong>in</strong>ked) sited <strong>in</strong> staircase enclosure, land<strong>in</strong>gs,hallways, lobbies, and to the circulation spaces of any multi-roomunits. Smoke alarms (<strong>in</strong>terl<strong>in</strong>ked) sited <strong>in</strong> bedrooms, liv<strong>in</strong>g rooms andbedsits without cook<strong>in</strong>g facilities. Heat alarms (<strong>in</strong>terl<strong>in</strong>ked) sited <strong>in</strong> kitchens and bedsits conta<strong>in</strong><strong>in</strong>gcook<strong>in</strong>g facilities. In bedsits conta<strong>in</strong><strong>in</strong>g cook<strong>in</strong>g facilities, <strong>in</strong> addition to the heat alarmthere should be a non-<strong>in</strong>terl<strong>in</strong>ked smoke alarm, with battery backup,wired to the local light<strong>in</strong>g circuit and to sound only <strong>in</strong> the roomconcerned.THREE, FOUR, FIVE OR SIX STOREY HOUSE WHICHPROVIDES BEDSIT-TYPE ACCOMMODATIONHMOs where one or more level exceeds 4.5m above ground and/or any flooris greater than 200 m 2 <strong>in</strong> areaGrade A System <strong>Fire</strong> detection and alarm system designed and <strong>in</strong>stalled <strong>in</strong>accordance with BS 5839: Part 1, except clauses relat<strong>in</strong>g to alarmaudibility, alarm warn<strong>in</strong>gs <strong>for</strong> the hear<strong>in</strong>g impaired, manual callpo<strong>in</strong>ts, capacity of standby batteries, and radio-l<strong>in</strong>ked systems whichare replaced by BS 5839: Part 6. Control panel to standard of BS EN 54-2 (power supply to BS EN54-4)..<strong>London</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>Guidance</strong> <strong>for</strong> <strong>Houses</strong> <strong>in</strong> Multiple OccupationVersion 2: 06/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!