12.07.2015 Views

analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet

analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet

analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

351579-YTS-B-0608Table 5: Settable System ParametersAddress Function Unit Range Default Your Settings1 Run test ON-OFF OFF2 Fan on delay-Heating Sec 0-30 303 Fan off delay-Heating Sec 0-255 604 Fan on delay-Cooling Sec 0-30 05 Fan off delay-Cooling Sec 0-255 306 Fac<strong>to</strong>ry setting - - 1 Do not change7 Suspend Cont Fan when starting Heating ON-OFF OFF8 Construction Mode - ON-OFF OFF9 Unoccupied Override Time Period Minutes 0-240 6010 Occupied Cooling Setpoint °F 45-99 7211 Occupied Heating Setpoint °F 45-99 6812 Unoccupied Cooling Setpoint °F 45-99 8513 Unoccupied Heating Setpoint °F 45-99 6014 SAT Control-Cooling ON-OFF ON-OFF ON15 Cooling SAT Control Setpoint °F 40-65 5016 SAT Control for Heating ON-OFF ON-OFF ON17 Heating SAT Control Setpoint °F 100-180 13518 Hydronic Heating ON-OFF ON-OFF OFF19 First Stage Hydronic Heating SAT Setpoint °F 80-180 12020 Second Stage Hydronic Heating SAT Setpoint °F 80-180 15021 Hydronic Heating Reverse Actuated Valve ON-OFF ON-OFF OFF22 Remote Control ON-OFF ON-OFF OFF23 VAV Upper Cooling SAT °F 40-70 6024 VAV Lower Cooling SAT °F 40-70 5525 VAV SAT Reset Setpoint °F 40-85 7226 VAV Occupied Setpoint ON-OFF ON-OFF OFF27 VAV Occupied Heating Setpoint °F 40-85 6828 Morning Warm-Up ON-OFF ON-OFF ON29 Morning Warm-Up RAT °F 50-85 7030 Duct Static Setpoint " H2O 0 – 5” 1.5”31 Building Pressure Setpoint " H2O neg .25 <strong>to</strong> .25 .1”32 Economizer ON-OFF ON-OFF ON33 Economizer First Stage °F 40-65 5534 Economizer Second Stage °F 40-65 5035 Economizer Minimum Position Percent 0 <strong>to</strong> 100% 2036 Outside Air Humidity Sensor ON-OFF ON-OFF OFF37 Economizer Outside Air Enthalpy Setpoint BTUs Per Pound 10-50 2738 Return Air Humidity Sensor ON-OFF ON-OFF OFF39 Economizer OAT Enable °F 40-80 5540 Demand Ventilation ON-OFF ON-OFF OFF41 IAQ Sensor Range PPM 0-5000 200042 Demand Ventilation Setpoint PPM 0-5000 100043 Power Exhaust ON-OFF ON-OFF ON44 Modulating Exhaust ON-OFF ON-OFF OFF45 Exhaust VFD Installed ON-OFF ON-OFF OFF46Exhaust Damper Position for Exhaust Fan <strong>to</strong>Turn On (Modulating Only)% Of Damper Position 0-100 80%16 Johnson Controls Unitary Products

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!