351579-YTS-B-0608mizer damper and using more outdoor air. However, if theeconomizer algorithm can not prevent the SAT fromincreasing above the <strong>to</strong>p control band limit by closing theeconomizer damper <strong>to</strong> its programmed minimum position,one or more compressors may need <strong>to</strong> be turned on. Similarly,if the economizer algorithm can not prevent the SATfrom dropping below the bot<strong>to</strong>m control band limit byopening the economizer damper, one or more heatingstages may need <strong>to</strong> be turned on.• If the OAT is within the SAT control band, i.e. between theprogrammed "Comfort Ventilation Upper Setpoint" and"Comfort Ventilation Lower Setpoint", the economizerdamper is driven <strong>to</strong> the fully open position. In this case, noother control action needs <strong>to</strong> be taken <strong>to</strong> maintain the SATwithin the specified control band.STAGING CONTROL DURING COMFORT VENTILATIONThe economizer control alone may not be able <strong>to</strong> maintain theSAT within the specified control band. A separate stagingcontrol algorithm supplements the economizer control and willstage heating, or mechanical cooling as necessary. If the SATincreases above the "Comfort Ventilation Upper Setpoint" formore than 5 minutes, the control will destage a heating stage (ifany heating stages running), or add a compressor. The controlwill repeat this process every 5 minutes until the SAT gets back<strong>to</strong> within the control band.If the SAT drops below the "Comfort Ventilation Low Supply AirSetpoint" for more than 5 minutes, the control will destage acompressor (if any compressors running), or add a heatingstage. The control will repeat this every 5 minutes until the SATgets back <strong>to</strong> within the control band. As the heating stages, orcompressors are staged up, or destaged, the economizercontrols continues using the economizer damper <strong>to</strong> "trim" theeffect of the staging and <strong>to</strong> maintain the SAT as near the middleof the SAT control band as possible.If the unit is using hydronic heat, the control modulates thewater valve <strong>to</strong> maintain SAT at the programmed "ComfortVentilation Low Supply Air Setpoint". At this setpoint, thehydronic heat control does not conflict with the economizercontrol, and will prevent SAT from dropping outside of thespecified control band when the economizer can no longermaintain the SAT at its middle-of-the-band setpoint.HYDRONIC HEATThe Hydronic Heat option requires relocating the SAT sensordownstream of the heating coil.During hydronic heating, the SAT control <strong>to</strong> the selected“Hydronic Heat First Stage SAT setpoint”, or “Hydronic HeatSecond Stage SAT Setpoint” is performed using a Proportional /Integral control algorithm. The control algorithm includesspecial provisions (sometimes referred <strong>to</strong> as a “bumplesstransfer” feature) that allow it <strong>to</strong> resume control of SAT as fastas possible when it is re-activated during the ON / OFF cyclingof the unit (cycling between a satisfied and a heating stateunder control of a zone thermostat, or zone sensor). In its OFFstate,the control algorithm continues moni<strong>to</strong>ring the SAT andperforms calculations necessary <strong>to</strong> set its output, that controlsthe hot water valve, <strong>to</strong> have the same value on starting the ONcycleas it had when it went in<strong>to</strong> the OFF-cycle (in spite of somedecrease in the SAT during the OFF-cycle).The “bumpless transfer” feature of the hydronic heat controlalgorithm essentially acts similar <strong>to</strong> a “memory” that holds thealgorithm output during the OFF-cycles. This “memory” is rese<strong>to</strong>nly on unit shutdown. The effect of this “memory” can beobserved on the action of the hot water valve. After unit startup(during the first ON-cycle of the hydronic heat), there is no“memorized” output value and the valve moves relatively slowlyin<strong>to</strong> a control position required <strong>to</strong> maintain the SAT setpoint. Onsubsequent ON cycles, the valve moves in<strong>to</strong> a control positionmuch faster as dictated by the output value s<strong>to</strong>red in controlalgorithm “memory”.COOLING LOCKOUT ON OATThis is the Outside Air Temperature Setpoint that the controluses <strong>to</strong> lock out mechanical cooling when the OAT is below thissetpoint. There is a one-degree hysteresis on each side of thesetpoint. Adjustable from 0 °F <strong>to</strong> 100 °F, the default is 45 °F.The change <strong>to</strong> 0 °F applies only <strong>to</strong> compressors # 1 and # 2when head pressure control is installed. Cooling Lockout onOAT may occur while the control is in an Economizer mode andthere is a demand for compressors.WATER COIL FREEZE STAT (FSI)This option is used only on roof<strong>to</strong>p units with hydronic heat(Hydronic heat option is turned ON). When the FSI terminalsees 24 VAC, the control will open the Hot Water valve <strong>to</strong>100%. The control will continue <strong>to</strong> drive the valve <strong>to</strong> 100% untilfive minutes after the switch has closed. If the control isoperating the Fan, it will close the Economizer fully until thefreeze condition is over. If the fan is off and the RAT dropsbelow 40 °F, the Hot Water Valve will turn on 100%. This controlsequence takes place regardless of the supply fan status (it isexpected <strong>to</strong> be used/ needed mostly in situations when thesupply fan is not running). A Hot Water Coil Freeze Alarm isgenerated. The alarm is written <strong>to</strong> the Error His<strong>to</strong>ry Buffer. Innetworked applications, the alarm flag is readable by thenetwork.After the valve override sequence described above iscompleted, the valve will revert <strong>to</strong> normal operation and thealarm is au<strong>to</strong>matically reset. The same sequence is repeatedevery time the Hot Water Coil Freeze Switch opens (infiniteretries).CV OPERATIONThe paragraphs below identify control modes of CV operationand provide an overview of control methods in all modes. Themodes include Occupied and Unoccupied Heating and Cooling,and differ depending on the method used <strong>to</strong> control zonetemperature (thermostat, or a space sensor). The heating vs.cooling modes are entered under control of the thermostat, or,in case of space sensor, control algorithm detecting zonecooling or heating demand. The "occupied" vs. "unoccupied"Johnson Controls Unitary Products 29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!