351579-YTS-B-0608Table 5: Settable System Parameters (Continued)Address Function Unit Range Default Your Settings474849Exhaust Damper Position for Exhaust Fan <strong>to</strong>Turn Off (Modulating Only)Economizer Damper Position for Exhaust Fan<strong>to</strong> Turn On (Non-Modulating Only)Economizer Damper Position for Exhaust Fan<strong>to</strong> Turn Off (Non-Modulating Only)% Of Damper Position 0-100 20%% Of Damper Position 0-100 60%Percent of EconomizerPosition0-100% 20%50 APS Data Open-Closed Open-Closed Open51 Dirty Filter Switch ON-OFF ON-OFF OFF52 Dirty Filter Switch Data Open-Closed Open-Closed Open53 Cooling Mode Enable ON-OFF ON-OFF ON54 Heating Mode Enable ON-OFF ON-OFF ON55 Fan On Mode with the Sensor Option ON-OFF ON-OFF ON56 Space Setpoint Offset °F -5 <strong>to</strong> 5 0 degrees57 Metric Operation ON-OFF ON-OFF OFF58 BAS Economizer ON-OFF ON-OFF OFF59 Year Year 00-99 460 Month Month Number 161 Day of Month Day Number 162 Day of Week Day Number 163 Hour Hour 0-23 064 Minute Minutes 0-59 065 SAT (Supply Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only66 RAT (Return Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only67 OAT (Outside Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only68 ST (Space Temp) °F -40 <strong>to</strong> 180 Read Only Read Only69 OAH (Outside Air Hum) %RH 0 <strong>to</strong> 100% Read Only Read Only70 RAH (Return Air Hum) %RH 0 <strong>to</strong> 100% Read Only Read Only71 Occupied Input Enable ON-OFF ON-OFF OFF72 Alarm ArrayRead OnlyRead Only73 Alarm Array Read Only Read Only74 Alarm ArrayThese values represent the last 5 alarm codes inmemory. 72 is latest & 76 oldest.Read Only Read Only75 Alarm Array Read Only Read Only76 Alarm Array Read Only Read Only77 CV/VAV Mode Read Only Flag CV=0 VAV=1 Read Only Read Only78 Hot Gas Reheat ON-OFF ON-OFF OFF79 Hot Gas Bypass ON-OFF ON-OFF OFF80 Compressors Number 2 <strong>to</strong> 4 Fac<strong>to</strong>ry Set81 Heat Stages Number 0 <strong>to</strong> 3 Fac<strong>to</strong>ry Set82 Duct Static Reading Inches Water 0 <strong>to</strong> 5.0” Read Only83 Building Pressure Reading Inches Water 0 <strong>to</strong> 5.0” Read Only84 Low Ambient Kit Installed ON-OFF ON-OFF Fac<strong>to</strong>ry Set85 Building Static Pressure Sensor Enable ON-OFF ON-OFF Fac<strong>to</strong>ry Set86 ERV Installed ON-OFF ON-OFF Fac<strong>to</strong>ry Set87 ERV Unoccupied Fan ON-OFF ON-OFF Fac<strong>to</strong>ry Set88 Duct Static Shutdown Setpoint Inches Water 0 <strong>to</strong> 5.0” 4.5”NOTES:For On/Off functions, 1 is ON and 0 is OFFRead only items are readings from sensors which only change as the measured condition changes.Johnson Controls Unitary Products 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!