analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet
analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet
analog to digital converter . . . . . . . . . . . . . . . 4 - UPGNet
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
351579-YTS-B-0608Table 5: Settable System Parameters (Continued)Address Function Unit Range Default Your Settings474849Exhaust Damper Position for Exhaust Fan <strong>to</strong>Turn Off (Modulating Only)Economizer Damper Position for Exhaust Fan<strong>to</strong> Turn On (Non-Modulating Only)Economizer Damper Position for Exhaust Fan<strong>to</strong> Turn Off (Non-Modulating Only)% Of Damper Position 0-100 20%% Of Damper Position 0-100 60%Percent of EconomizerPosition0-100% 20%50 APS Data Open-Closed Open-Closed Open51 Dirty Filter Switch ON-OFF ON-OFF OFF52 Dirty Filter Switch Data Open-Closed Open-Closed Open53 Cooling Mode Enable ON-OFF ON-OFF ON54 Heating Mode Enable ON-OFF ON-OFF ON55 Fan On Mode with the Sensor Option ON-OFF ON-OFF ON56 Space Setpoint Offset °F -5 <strong>to</strong> 5 0 degrees57 Metric Operation ON-OFF ON-OFF OFF58 BAS Economizer ON-OFF ON-OFF OFF59 Year Year 00-99 460 Month Month Number 161 Day of Month Day Number 162 Day of Week Day Number 163 Hour Hour 0-23 064 Minute Minutes 0-59 065 SAT (Supply Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only66 RAT (Return Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only67 OAT (Outside Air Temp) °F -40 <strong>to</strong> 180 Read Only Read Only68 ST (Space Temp) °F -40 <strong>to</strong> 180 Read Only Read Only69 OAH (Outside Air Hum) %RH 0 <strong>to</strong> 100% Read Only Read Only70 RAH (Return Air Hum) %RH 0 <strong>to</strong> 100% Read Only Read Only71 Occupied Input Enable ON-OFF ON-OFF OFF72 Alarm ArrayRead OnlyRead Only73 Alarm Array Read Only Read Only74 Alarm ArrayThese values represent the last 5 alarm codes inmemory. 72 is latest & 76 oldest.Read Only Read Only75 Alarm Array Read Only Read Only76 Alarm Array Read Only Read Only77 CV/VAV Mode Read Only Flag CV=0 VAV=1 Read Only Read Only78 Hot Gas Reheat ON-OFF ON-OFF OFF79 Hot Gas Bypass ON-OFF ON-OFF OFF80 Compressors Number 2 <strong>to</strong> 4 Fac<strong>to</strong>ry Set81 Heat Stages Number 0 <strong>to</strong> 3 Fac<strong>to</strong>ry Set82 Duct Static Reading Inches Water 0 <strong>to</strong> 5.0” Read Only83 Building Pressure Reading Inches Water 0 <strong>to</strong> 5.0” Read Only84 Low Ambient Kit Installed ON-OFF ON-OFF Fac<strong>to</strong>ry Set85 Building Static Pressure Sensor Enable ON-OFF ON-OFF Fac<strong>to</strong>ry Set86 ERV Installed ON-OFF ON-OFF Fac<strong>to</strong>ry Set87 ERV Unoccupied Fan ON-OFF ON-OFF Fac<strong>to</strong>ry Set88 Duct Static Shutdown Setpoint Inches Water 0 <strong>to</strong> 5.0” 4.5”NOTES:For On/Off functions, 1 is ON and 0 is OFFRead only items are readings from sensors which only change as the measured condition changes.Johnson Controls Unitary Products 17