351579-YTS-B-0608Table 3: Simplicity ® Control InputsName Range Resolution Precision DescriptionY1 18 - 30 VAC On - Off +/- .5 VAC Request for the first stage of Cooling (24 VAC sense) Tstat Screw TerminalY2 18 - 30 VAC On - Off +/- .5 VAC Request for the second stage of Cooling (24 VAC sense) Tstat Screw TerminalY3 18 - 30 VAC On - Off +/- .5 VAC Request for the third stage of Cooling (24 VAC sense) Tstat Screw TerminalY4 18 - 30 VAC On - Off +/- .5 VAC Request for the fourth stage of Cooling (24 VAC sense) Tstat Screw TerminalW1 18 - 30 VAC On - Off +/- .5 VAC Request for the first Stage of Heating (24 VAC sense) Tstat Screw TerminalW2 18 - 30 VAC On - Off +/- .5 VAC Request for the second Stage of Heating (24 VAC sense) Tstat Screw TerminalW3 18 - 30 VAC On - Off +/- .5 VAC Request for the third Stage of Heating (24 VAC sense) Tstat Screw TerminalG 18 - 30 VAC On - Off +/- .5 VAC Request for the Fan (24 VAC sense) Tstat Screw TerminalR 18 - 30 VAC - -These terminals are a ¼' Female Fas<strong>to</strong>n and a Thermostat Screw terminalconnected <strong>to</strong> the power supply of the board.C Earth Ground - - These terminals are a ¼' Fas<strong>to</strong>n and a Thermostat Screw terminal.OCC 18 - 30 VAC On - Off +/- .5 VAC Occupied input (24 VAC sense) Tstat Screw TerminalSD 18 - 30 VAC - +/- .5 VAC Shut Down input Tstat Screw TerminalPurge 18 - 30 VAC On - Off +/- .5 VAC Building Purge input (24 VAC sense) Tstat Screw TerminalBAS Economizer 2 - 10 VDC Not Read by micro - Input that routes <strong>to</strong> the Economizer output Two Tstat Screw Terminals +&-HPS1 18 - 30 VAC On - Off +/- .5 VAC High Pressure Switch for Circuit # 1 (24 VAC sense)HPS2 18 - 30 VAC On - Off +/- .5 VAC High Pressure Switch for Circuit # 2 (24 VAC sense)HPS3 18 - 30 VAC On - Off +/- .5 VAC High Pressure Switch for Circuit # 3 (24 VAC sense)HPS4 18 - 30 VAC On - Off +/- .5 VAC High Pressure Switch for Circuit # 4 (24 VAC sense)LPS1 18 - 30 VAC On - Off +/- .5 VAC Low Pressure Switch for Circuit # 1 (24 VAC sense)LPS2 18 - 30 VAC On - Off +/- .5 VAC Low Pressure Switch for Circuit # 2 (24 VAC sense)LPS3 18 - 30 VAC On - Off +/- .5 VAC Low Pressure Switch for Circuit # 3 (24 VAC sense)LPS4 18 - 30 VAC On - Off +/- .5 VAC Low Pressure Switch for Circuit # 4 (24 VAC sense)Limit Switch 1 18 - 30 VAC On - Off +/- .5 VAC High Limit Switch input (24 VAC sense) For Burner section 1Limit Switch 2 18 - 30 VAC On - Off +/- .5 VAC High Limit Switch input (24 VAC sense) For Burner section 2Limit Switch 3 18 - 30 VAC On - Off +/- .5 VAC High Limit Switch input (24 VAC sense) For Burner section 3GV1 18 - 30 VAC On - Off +/- .5 VAC Gas Valve input (24 VAC sense) For Burner section 1GV2 18 - 30 VAC On - Off +/- .5 VAC Gas Valve input (24 VAC sense) For Burner section 2GV3 18 - 30 VAC On - Off +/- .5 VAC Gas Valve input (24 VAC sense) For Burner section 3Test / Reset / Up ON - Off ON - Off - Test / Reset But<strong>to</strong>n and Increment Data InputAddress / Down ON - Off ON - Off - Address But<strong>to</strong>n and Decrement Data InputAlarms / Advance Data ON - Off ON - Off - Alarm But<strong>to</strong>n and Advance Data InputProgram ON - Off ON - Off - Program But<strong>to</strong>n InputReal Time ClockWater Coil Freeze Stat(FSI)Supply Air Temp Sensor(SAT)Outside Air Temp Sensor(OAT)Space Temp Sensor(ST)Return Air Temp Sensor(RAT)Space Setpoint Offset(SSA)Building PressureSensor(BPS)Duct Pressure Sensor(DPS)24 hours, 365 Daysincluding Leap yearand DaylightSavings TimeSeconds - Real Time Clock Chip18 - 30 VAC On - Off +/- .5 VAC Hot Water Freeze Stat (24 VAC sense) two ¼ Fas<strong>to</strong>ns-40° - +180° F .1° F-40° - +180° F .1° F-40° - 180 °F+/- 2 °F acrossrange-40° - 180 °F+/- 2 °F acrossrangeThis is a 10KΩ type 3 Thermis<strong>to</strong>rThis is a 10KΩ type 3 Thermis<strong>to</strong>r32° - 100° F .1° F .5° F This is a 10KΩ type 3 Thermis<strong>to</strong>r-40° - +180° F .1° F-40° - 180 °F+/- 2 °F acrossrange0 - 20 KΩ 1 KΩ + and - 250 Ω0 - 5 VDC-.25 - +.25"WC.001 "WC0 - 5 VDC0 - 5 "WC .01 "WC.005 "WC1% Across range.05 "WC 1%across rangeThis is a 10KΩ type 3 Thermis<strong>to</strong>r3 position Mini Screw Terminal shared with Space Temp The common terminalin the center is common for both the Space Temp and Setpoint Offset.0 - 5 volt input0 - 5 volt inputAPS (APS) 18 - 30 VAC On - Off +/- .5 VAC Air Proving Switch (24 VAC sense)Fan Overload (FOVR) 18 - 30 VAC On - Off +/- .5 VAC Fan Overload Switch (24 VAC sense)CV / VAV Input 0 - 20 KΩ 1Ω + / - 5 Ω Resistive Input 0 - 5.5K = CV 10K - 20K = VAVJohnson Controls Unitary Products 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!