Flags displayed on Laboratory, Patient, and Quality Control Reports ...

Flags displayed on Laboratory, Patient, and Quality Control Reports ...

Flags displayed on Laboratory, Patient, and Quality Control Reports ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Flags</str<strong>on</strong>g> <strong>and</strong> Codes <strong>on</strong> <strong>Reports</strong><str<strong>on</strong>g>Flags</str<strong>on</strong>g> <str<strong>on</strong>g>displayed</str<strong>on</strong>g> <strong>on</strong> <strong>Laboratory</strong>, <strong>Patient</strong>, <strong>and</strong> <strong>Quality</strong> C<strong>on</strong>trol <strong>Reports</strong>Flag Descripti<strong>on</strong> C<strong>on</strong>diti<strong>on</strong> Acti<strong>on</strong>>DR Above Dynamic Range The result is above the dynamic range for the analyte. Dilute the sample. Refer to the appropriate package insert <strong>and</strong> assay methodology sheet.SR Above Supplementary Range The result is above the defined supplementary range for the analyte.


<str<strong>on</strong>g>Flags</str<strong>on</strong>g> <strong>and</strong> Codes <strong>on</strong> <strong>Reports</strong>Code Descripti<strong>on</strong> C<strong>on</strong>diti<strong>on</strong> Acti<strong>on</strong>ODOperator Requested Diluti<strong>on</strong>The assay was automatically diluted <strong>and</strong> the result calculated using the operator requested factorreported in the Dil (Diluti<strong>on</strong>) field. The result reported is for the lowest diluti<strong>on</strong> factor reportedwhen multiple diluti<strong>on</strong> factors are requested.No acti<strong>on</strong> necessary.OR Outside Range The result is outside the dynamic or supplementary ranges. Check for dynamic or supplementary range flags <strong>and</strong> follow the recommended acti<strong>on</strong>s.PF Predicti<strong>on</strong> Failure The master computer detected an invalid well reading or did not process valid well readings. Check for additi<strong>on</strong>al codes <strong>and</strong> for c<strong>on</strong>diti<strong>on</strong> codes that occurred at or near the report print time.RC Reference C<strong>on</strong>sistency The Luminometer or Incubator reference readings for the well are outside specificati<strong>on</strong>s.Check the c<strong>on</strong>diti<strong>on</strong> codes for related Luminometer c<strong>on</strong>diti<strong>on</strong>s <strong>and</strong> perform the recommendedprocedures.RDReflex DilutedThe assay was automatically diluted <strong>and</strong> result calculated using the c<strong>on</strong>figured diluti<strong>on</strong> factorreported in the Dil (Diluti<strong>on</strong>) field.No acti<strong>on</strong> necessary.RE Reagent Expired The assay was processed from an expired reagent pack or signal reagent. Load a new reagent pack or a new signal reagent pack.RP Reflex Processed The assay was automatically reflex processed. No acti<strong>on</strong> necessary.RRRecalculated ResultThe result was recalculated using the Recalculate Results functi<strong>on</strong> <strong>on</strong> the Review Results -Review Edit Results screen.No acti<strong>on</strong> necessary.SC Spread Check A replicate result exceeded the percentage spread limit for the mean defined for the reagent lot.UC User Calibrati<strong>on</strong> The calibrati<strong>on</strong> parameters for this assay were entered manually.WT Well Temperature The well wash temperature is outside specificati<strong>on</strong>s.Check for additi<strong>on</strong>al codes <strong>and</strong> for c<strong>on</strong>diti<strong>on</strong> codes that occurred at or near the time the replicateswere processed. Repeat the assay, sample, or calibrati<strong>on</strong>.No acti<strong>on</strong> necessary. User calibrati<strong>on</strong>s are defined <strong>on</strong> the Opti<strong>on</strong>s & C<strong>on</strong>figurati<strong>on</strong> - Review/UserCalibrati<strong>on</strong>s screen.Check the c<strong>on</strong>diti<strong>on</strong> codes for potential causes <strong>and</strong> acti<strong>on</strong>s; check envir<strong>on</strong>mental m<strong>on</strong>itoring for out-ofrangetemperatures.ZS Zero Set Negative derived test result. Check for additi<strong>on</strong>al codes <strong>and</strong> flags.Refer to your VITROS ECi/ECiQ Immunodiagnostic System Operator’s Guide for more detailed informati<strong>on</strong>.©Ortho-Clinical Diagnostics, Inc., 2012 ■ VITROS ® is a trademark of Ortho-Clinical Diagnostics, Inc. ■ 100 Indigo Creek Drive ■ Rochester, NY 14626 Part No. J11794_EN 2012-12-07

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!