<strong>MI</strong> <strong>019</strong>-<strong>120</strong> – June 20113. Wiring3. Unscrew and remove the junction box from the flowtube using a suitable tool (such asa length of pipe inserted in the conduit entrance). Remove all thread sealant residue.4. Apply sealant to all male threads.5. Insert the flowtube wiring through the coupling, nipple, and base of junction box andengage the threads.6. Tighten the assembly, locating the conduit entrance as desired.7. Reconnect the flowtube wiring to the appropriate terminals (see Figure 16) andtighten the screws.! CAUTIONNo bare wire should be visible at the terminals. Ensure that the wire insulation has notprevented electrical contact.8. Dress excess flowtube wire within the junction box as necessary.NIPPLECOUPLINGSignal Cable PreparationFigure 15. Junction Box ExtensionIf conduit is to be used, run the unprepared end of the cable through the conduit from thetransmitter.Flowtube End1. Cut the flowtube end of the cable to length and strip back the jacket approximately127 mm (4 in).2. Separate the twisted pair conductors from their wrappers, shields, and drain wires.The wire pairs should remain twisted for ease of identification.3. Trim the shields, wrappers, and drain wires back to the jacket interface.22