Pressurising from an external pressure source<br />
A pressure-reducing valve must be fitted between the gas cylinder <strong>and</strong> the outlet connection of<br />
the hose. The maximum pressure on the outlet side of the reducing valve must not exceed<br />
18.9 bar (275 psi).<br />
To pressurise the pedestal from an external pressure source, proceed as follows:<br />
20<br />
WARNING!<br />
DO NOT adjust the pressure relief valve. Personal injury <strong>and</strong> pedestal<br />
damage may occur.<br />
(a) (b)<br />
Fig. 5 Column lock<br />
(a) locked/ON position, (b) unlocking/OFF position<br />
1. Set the column lock [6] to the ON position <strong>and</strong> fully depress the moving column [32]<br />
until the column lock engages (Fig. 5).<br />
2. Rotate the steering ring [19], so that the pressure gauge [1] is visible through the<br />
window (remove a trim weight, if necessary).<br />
3. Remove the Schrader valve cap [3] <strong>and</strong> connect the charging line from the pressure<br />
source.<br />
4. Turn on the pressure supply <strong>and</strong> slowly increase the pedestal pressure to the<br />
required pressure. Do not exceed the maximum working pressure indicated by the<br />
leading edge of the red sector on the gauge [1].<br />
WARNING!<br />
DO NOT exceed 7.2 bar (105 psi) without a balancing load installed.<br />
5. Disconnect the charging line, but do not refit the Schrader valve cap [3] at this stage.