02.12.2012 Views

Fusion FP-188 and FPH-188 - Vinten Radamec

Fusion FP-188 and FPH-188 - Vinten Radamec

Fusion FP-188 and FPH-188 - Vinten Radamec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Fusion</strong> <strong>FP</strong>-<strong>188</strong> pedestals <strong>and</strong> <strong>FP</strong>H-<strong>188</strong> height drives<br />

Selecting manual or robotic mode<br />

On the <strong>FP</strong>-<strong>188</strong> pedestal robotic control is independently selected for vertical (Z) column<br />

movement <strong>and</strong> horizontal (X <strong>and</strong> Y) pedestal movement. On the <strong>FP</strong>H-<strong>188</strong> only the vertical (Z)<br />

column can be controlled robotically, X,Y movement is manual.<br />

To engage the automatic height mode, proceed as follows:<br />

28<br />

WARNING!<br />

1. Display prominent warning signs in studios alerting personnel<br />

that robotic equipment is present <strong>and</strong> may move without<br />

warning.<br />

2. Only operate the pedestal remotely if you are able to see it, to<br />

avoid obstacles <strong>and</strong> collision hazards.<br />

3. Only operate the pedestal on stable studio floor surfaces.<br />

DO NOT operate the pedestal near floor edges over which the<br />

pedestal may fall, as this can cause personal injury <strong>and</strong>/or<br />

damage the equipment.<br />

NOTE: Movement indicators will flash to warn when an <strong>FP</strong>-<strong>188</strong> pedestal moves across<br />

the floor.<br />

1. Rotate the cable release button [37] anti-clockwise <strong>and</strong> fully depress the moving<br />

column [32] under h<strong>and</strong> restraint to engage the robotic height drive.<br />

2. Depress <strong>and</strong> rotate the height mode knob [20] clockwise to select robotic operation.<br />

The column will remain depressed under the control of the robotic height drive.<br />

CAUTION! Ensure that the pedestal load is balanced before driving the column<br />

remotely, to prevent damage to the drive system (see Balancing the<br />

load on page 24 for instructions).<br />

To select manual column operation, proceed as follows:<br />

1. Fully depress the moving column under h<strong>and</strong> restraint <strong>and</strong> depress <strong>and</strong> rotate the<br />

height mode knob [20] anti-clockwise to select manual operation.<br />

2. Depress <strong>and</strong> rotate the cable release button [37] clockwise to disengage the robotic<br />

height drive.<br />

NOTE: It is only possible to depress <strong>and</strong> rotate the cable release button when the column<br />

is fully depressed.