13.07.2015 Views

Hawke Transit System catalogo

Hawke Transit System catalogo

Hawke Transit System catalogo

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SELECTION AND SPECIFICATION PROCEDURESelection and SpecificationThere are two main starting points in practice.A. Cables or pipes known, no frame.The ideal way, is when the numbers anddiameters of cable or pipe are known, inadvance of ordering the frame. The procedureshould then follow route A.B. Frame already installed.However, if a transit frame and cables orpipes are already installed, and sealingspecifications are to be determined later,follow route B.No frame, cable or pipe requirements to beadvised in future.If a frame only is required, and all cable/piperequirements are to be advised at a later datein the contract, install as large a frame as ispossible, and fill it with blank blocks.Modular Cable/Pipe Tolerant BlocksIn the Block Selector Table below, the firstcolumn indicates the module size, secondand third columns indicate minimum andmaximum diameters of cable or pipe whichcan be accommodated by each block.Blank Filler blocks are suffixed ‘0’e.g. 15/0 20/0 etc.Code NumbersFor ordering purposes block code numbersare made up from the numbers in columns 1and 2 and are indicated in column 5. i.e. A40 module block capable of accommodatingcable/pipe from 28mm diameter up to 31mmdiameter is denoted 4028. A HF prefixdenotes zero Halogen blocks.NOTE: Two insert blocks are required foreach cable or pipe.Selection and Specification Procedure120 x 60 x 5 Packaging Strip 1120 x 60 x 10 Packaging Strip 1A- Cables/pipes known, no frame B- Frame already installedSTART1. Check (or measure)cable/pipe diameters andnumbers1. Check (or measure) frame(s)size and model number2. Determine the blockrequirements per frame, usingthe design template onPage 352. Check cable or pipenumbers/diameters to gothrough frame (s)3. Determine the frame(s) sizerequired to accommodateblocks, not forgetting to useblank blocks to allow for futureexpansion3. Determine the blockrequirements per frame, usingthe design template onPage 354. Check with builder/construction/engineer/architectthat proposed frame will beaccomodated by building4. Check if the blockarrangements fit in frame(s)provided.YES?5. If YES,complete your order,including all stayplates,compresion blocks and blankblocks, arranged in theappropriate frame size (s),and return to <strong>Hawke</strong> - or your<strong>Hawke</strong> <strong>Transit</strong> Distributor - forchecking and orderconfirmation.NO5.If NO, consult withbuilder/construction/engineer/architect todetermine what frame(s) can beaccommodated, andcables/pipes required, beforere-specifying by startingat 1 above81. Packing strips are supplied as solid strips or with strips precut or scored into individual blocks:TA50 (1 solid block 120x60x5 mm) TA100 (1 solid block 120x60x10 mm)TA50 x 24 (24 pieces 5x60x5 mm) TA100 x 12 (1 block prescored x 12 pieces10x60x10 mm)www.hawke-hts.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!