13.07.2015 Views

Download Installation Manual (.pdf) - Heat Transfer Products, Inc

Download Installation Manual (.pdf) - Heat Transfer Products, Inc

Download Installation Manual (.pdf) - Heat Transfer Products, Inc

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

F. SYSTEM SETTING PROGRAM NAVIGATIONOnce the System Menu Access Code is confirmed, the user can begin to set the system setting menu. Use the arrow keys onthe display to navigate through the system setting program. To change a setting, press ENTER. System settings can be increased bypressing the UP ARROW and decreased by pressing the DOWN ARROW on the display. When done, press ENTER. Setting will stopblinking and you can move on to next setting. Press RESET to exit programming and store settings. Listed below are the heatersettings that can be programmed into the control.51SCREENFunction 1MODEVWH MODE 1Function 3DHW TANK MAX TEMP180 o F 3Function 4BURNER OFF DIFF20 o F 4Function 6VWH POST PUMP TIME0 MINUTES 6Function 7WARM WEATHER OFF68 o F 7Function 8MIN OUTDOOR TEMP5 o F 8Function 9MAX SUPPLY TEMP190 o F 9Function 10MAX OUTDOOR TEMP68 o F 10Function 11MIN SUPPLY TEMP95 o F 11Function 12MIN HEATER TEMP68 o F 12Function 13CH POST PUMP TIME0 MINUTES 13Function 14DHW PRIORITY30 MINUTES 14Function 15CASCADE ADDRESS0 15Function 16OPTIONAL INPUTRETURN SEN 16Function 170-10 VOLT FUNCTIONTEMPERATURE 17Function 18STEP MODULATE MODEON 18Function 19HEATER SUPPLY DHW180 o F 19Function 20WATER SAFETY INPUTWATER PRESSURE 20DESCRIPTIONFactory Program ModeThis screen indicates that the control is configured correctly for a volume water heater. Do not change this screen.DHW Tank Max TempThis is the maximum temperature that can be selected in heater settings for the DHW tank. Factory Default is 180 o F.(Range: 95 o F to 180 o F)Burner Off DifferentialThis is the amount of degrees above tank set point that the burner will maintain its outlet water temperature whilethere is a demand for heat. Factory Default is 20 o F. (Range: 1 o F to 45 o F)VWH Post Pump TimeThe heater pump has the ability to post purge energy from the heater to the tank after the set point has beenachieved. Please note that running the pump for a time greater than 5 minutes may cause tank energy to bereleased back to the heat exchanger. Factory Default of 0 Minutes. (Range: 0 – 10 minutes)Warm Weather ShutoffNot applicable on this product.Min Outdoor TempNot applicable on this product.Max Supply TempNot applicable on this product.Max Outdoor TempNot applicable on this product.Min Supply TempNot applicable on this product.Min <strong>Heat</strong>er TempNot applicable on this product.CH Post Pump TimeNot applicable on this product.DHW PriorityNot applicable on this product.Cascade AddressBus addressing heaters (maximum heaters allowed 8 in a cascade system). Master <strong>Heat</strong>er address is 0 andFollowing <strong>Heat</strong>ers are addressed 1 thru 7. Default: 0 (Range: 0 – 8). NOTE: DO NOT USE ADDRESS 8.Optional InputsAllows the user to select from optional inputs to control or monitor the system. Default: RETURN (Range: Off /Booster Board / 0-10 Volt / DHW Sensor / Return Sen).0-10 Volt FunctionAllows the user to control heater modulation through temperature control. Factory Default = Temperature(Temperature only on VWH).Step Modulation ModeNot applicable on this product.<strong>Heat</strong>er DHW TempNot applicable on this product.Water Safety InputThe user can select various water safety inputs used in the heater system. Default: Flow Switch (Range: None / LowWater Cut off / Flow Switch / Water Pressure).LP- 429 REV. 6.6.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!