13.07.2015 Views

EXSULATION® S5000 Mineral Wool Slab Non Combustible ... - Dryvit

EXSULATION® S5000 Mineral Wool Slab Non Combustible ... - Dryvit

EXSULATION® S5000 Mineral Wool Slab Non Combustible ... - Dryvit

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Exsulation® <strong>S5000</strong>EXS.0.0.05<strong>Dryvit</strong> Drainage Strip set indabs of AP AdhesiveApproved mechanical fixing<strong>Dryvit</strong> AquaFlash® meshembedded in <strong>Dryvit</strong> AquaFlashLiquid lapped over window flangeSee Protection of Rough Openingas per EXS.0.0.06 and EXS.0.0.07Approved substrate<strong>Dryvit</strong> water-resistive barrier coating<strong>Dryvit</strong> adhesive in vertical notched trowelconfiguration applied over secondary barrier<strong>Mineral</strong> wool insulation slab notched to accommodateDrainage Strip, flashing, and AquaFlash.<strong>Dryvit</strong> reinforcing mesh embedded in base coat<strong>Dryvit</strong> finishWrap <strong>Dryvit</strong> Detail Mesh 63.5 mm (2 1 2")min. at backside of insulation slab<strong>Dryvit</strong> Demandit or Color Prime onsurface(s) to receive sealant<strong>Dryvit</strong> compatible sealant with closed cell backer-rodand weep tubes every 600 mm (24"), by others19 mm (3/4") min.Provide air seal, by others,around interior of windowper window manufacturer'srequirementsWindow integral flashingWrap <strong>Dryvit</strong> Detail Mesh 63.5 mm (2 1 2")min. at backside of insulation slab<strong>Dryvit</strong> compatible sealant, by others<strong>Dryvit</strong> AquaFlash System<strong>Dryvit</strong> Demandit or Color Prime onsurface(s) to receive sealant19 mm (3/4") min.BY OTHERSDRYVIT EXSULATION<strong>S5000</strong> SYSTEMNotes:1. <strong>Dryvit</strong> recommends that ground floorapplications and all facades exposed toabnormal stress, high traffic, or deliberateimpact have the base coat reinforced withPanzer® 15 or 20 mesh prior to Standard Plusmesh. Location of high impact zones should beindicated on contract drawings.2. Additional head flashing may be necessary forwindows that are not self flashing.Sill pan flashing, by others<strong>Dryvit</strong> water-resistivebarrier coating<strong>Dryvit</strong> AquaFlashTransition flashing3. Install Mechanical Fixings as per EXS.0.0.03. Drainable Sill OptionR-002-07-08Head/Sill for Self Flashing Window OptionsDRYVIT SYSTEMS CANADA129 Ringwood Drive PO Box 1268Stouffville, Ontario L4A 8A2800-263-3308www.dryvit.com®The architecture, engineering and design of the project using the <strong>Dryvit</strong> products is theresponsibility of the project's design professional. All systems must comply with localbuilding codes and standards. This detail is for general information and guidance onlyand <strong>Dryvit</strong> Systems Canada specifically disclaims any liability for the use of this detailand/or for the architecture, design, engineering or workmanship of any project. Thedesign professional determines, at its sole discretion, whether this detail or a functionallyequivalent alternative is best suitedfor the project. Use of a functionally equivalent detaildoes not violate <strong>Dryvit</strong>'s warranty. This detail is subject to change without notice.Contact <strong>Dryvit</strong> Systems Canada to ensure you have the most recent version.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!