13.07.2015 Views

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

www.leoni-<strong>in</strong>dustrial-projects.com FOUNDATION Fieldbus 100 Ω 35ICON® BusLong Distance 70 °C AWG 16 Long Distance 70 °C AWG 14FOUNDATION FieldbusH1 100 ΩTrunk cable <strong>for</strong> fixed <strong>in</strong>stallation <strong>in</strong>door and outdoor, on racks,trays, <strong>in</strong> conduits, <strong>in</strong> dry and wet locations. Between Segment-Coupler and “Field-Barrier-Device”. Recommended <strong>for</strong> use as fireTrunk cable <strong>for</strong> fixed <strong>in</strong>stallation <strong>in</strong>door and outdoor, on racks,trays, <strong>in</strong> conduits, <strong>in</strong> dry and wet locations. Between Segment-Coupler and “Field-Barrier-Device”. Recommended <strong>for</strong> use as fireApplicationprotection measure <strong>for</strong> people and important material assets. protection measure <strong>for</strong> people and important material assets.​ ​ Design79300605 79300607 Part. No.FB-2Y(St+Ce)H FB-2Y(St+Ce)H Type description1 x 2 x AWG 16/7 1 x 2 x AWG 14/7 Product sizeorange orange Colour​ ​ Constructionpla<strong>in</strong> annealed copper wire, stranded, size: AWG 16 pla<strong>in</strong> annealed copper wire, stranded, size: AWG 14 Conductorpolyethylene PE polyethylene PE Insulation(+)-core: orange, (-)-core: blue (+)-core: orange, (-)-core: blue Colour codeplastic coated alum<strong>in</strong>ium tape, metallic surface outside, <strong>in</strong>contact with t<strong>in</strong>ned copper dra<strong>in</strong> wire and t<strong>in</strong>ned copper wireplastic coated alum<strong>in</strong>ium tape, metallic surface outside, <strong>in</strong>contact with t<strong>in</strong>ned copper dra<strong>in</strong> wire and t<strong>in</strong>ned copper wire Collective screenbraidbraidlow smoke zero halogen flame retardant compound LSZH low smoke zero halogen flame retardant compound LSZH Outer sheath material7.5 x cable diameter 7.5 x cable diameter M<strong>in</strong>. bend<strong>in</strong>g radius- repeated bend<strong>in</strong>g115 kg/km 160 kg/km Cable weight​ ​ Temperature Range-30°C up to +70°C -30°C up to +70°C - dur<strong>in</strong>g operation-5°C up to +50°C -5°C up to +50°C - dur<strong>in</strong>g <strong>in</strong>stallation​ ​ Electrical Properties at 20 °C28.5 Ω/km 17.9 Ω/km Conductor resistance (loop) max.12 Ω/km 12 Ω/km Screen resistance nom.60 nF/km 60 nF/km Mutual capacitance nom.0.7 mH/km 0.7 mH/km Inductance nom2 nF/km 2 nF/km Capacit. unbalance to earth max.100 Ω ± 20 Ω 100 Ω ± 20 Ω Impedance at f = 31.25 kHz3.0 dB/km 3.0 dB/km Attenuation at f = 39 kHz max.1.7 μs/km 1.7 μs/km Propagation delay changemax. (f = 7.9 kHz - 39 kHz)Other propertiesFlame retardantUL 13 (vertical tray) UL 13 (vertical tray) - Test on s<strong>in</strong>gle cableIEC 60332-3-24 (Cat. c) IEC 60332-3-24 (Cat. c) - Test on bunched cablesICEA S-73-532 (*) ICEA S-73-532 (*) Oil resistanceUL 1581 section 1200 UL 1581 section 1200 Sunlight resistanceM 16 M 16 Connectors / glandsFurther cable variations, part numbers and UL listed types on page 46.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!