13.07.2015 Views

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.leoni-<strong>in</strong>dustrial-projects.com CAN Bus 120 Ω 55Multipair 90 °C with steel wire armour Multipair 90 °C with steel wire armour CAN Bus 120 ΩFor <strong>transmission</strong> of CAN (Control Area Network) bus signals orcomputer signals with RS 485 or RS 422 <strong>in</strong>terface. Suitable <strong>for</strong>For <strong>transmission</strong> of CAN (Control Area Network) bus signals orcomputer signals with RS 485 or RS 422 <strong>in</strong>terface. Suitable <strong>for</strong> Applicationdirect burial and <strong>in</strong>creased mechanical stresses.direct burial and <strong>in</strong>creased mechanical stresses.​ ​ Design7924000U 7924002U Part. No.FB-v2XCeYSWAY-fl PiMF FB-v2XCeYSWAY-fl PiMF Type description2 x 2 x AWG 24/7 PiMF 4 x 2 x AWG 24/7 PiMF Product sizeblack black Outer sheath colour​ ​ Constructiont<strong>in</strong>ned annealed copper wire, stranded, size: AWG 24 t<strong>in</strong>ned annealed copper wire, stranded, size: AWG 24 Conductorcross-l<strong>in</strong>ked polyethylene XLPE cross-l<strong>in</strong>ked polyethylene XLPE Insulationwhite/blue, white/orange white/blue, white/orange, white/green, white/brown Colour codeplastic coated alum<strong>in</strong>ium tape, metallic surface outside, <strong>in</strong> plastic coated alum<strong>in</strong>ium tape, metallic surface outside, <strong>in</strong>contact with collective screencontact with collective screenIndividual screent<strong>in</strong>ned copper wire braid, opt. coverage approx. 80 %, <strong>in</strong> t<strong>in</strong>ned copper wire braid, opt. coverage approx. 80 %, <strong>in</strong>contact with stranded t<strong>in</strong>ned copper dra<strong>in</strong> wirecontact with stranded t<strong>in</strong>ned copper dra<strong>in</strong> wireCollective screenpolyv<strong>in</strong>yl chloride PVC, black polyv<strong>in</strong>yl chloride PVC, black Inner sheath 1 materialgalvanised round steel wires galvanised round steel wires Armourpolyv<strong>in</strong>yl chloride PVC polyv<strong>in</strong>yl chloride PVC Outer sheath material10 x cable diameter 10 x cable diameter M<strong>in</strong>. bend<strong>in</strong>g radius- repeated bend<strong>in</strong>g14.6 mm 16.3 mm Outer dia.360 kg/km 420 kg/km Cable weight​ ​ Temperature Range-30°C up to +90°C -30°C up to +90°C - dur<strong>in</strong>g operation-5°C up to +50°C -5°C up to +50°C - dur<strong>in</strong>g <strong>in</strong>stallation​ ​ Electrical Properties at 20 °C184.8 Ω/km 184.8 Ω/km Conductor resistance (loop) max.42 nF/km 42 nF/km Mutual capacitance nom.0.7 mH/km 0.7 mH/km Inductance nom.120 Ω ± 10 Ω 120 Ω ± 10 Ω Impedance at f = 1 MHz24 dB/km 24 dB/km Attenuation at f = 1 MHz nom.​ ​ Other propertiesFlame retardantUL 13 (vertical tray) UL 13 (vertical tray) - Test on s<strong>in</strong>gle cableIEC 60332-3-24 (Cat. c) IEC 60332-3-24 (Cat. c) - Test on bunched cablesICEA S-73-532 ICEA S-73-532 Oil resistanceUL 1581 section 1200 UL 1581 section 1200 Sunlight resistance

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!