13.07.2015 Views

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.leoni-<strong>in</strong>dustrial-projects.com Fieldbus technology 9Transmission systemsProfibus (Process Fieldbus)PROFIBUS DP (Decentralized Periphery)PROFIBUS DP was specially designed <strong>for</strong> rapid cyclical <strong>data</strong><strong>transmission</strong>. PROFIBUS DP uses RS-485 as a <strong>transmission</strong> technology<strong>for</strong> high <strong>data</strong> rates.PROFIBUS PA (Process Automation)The PROFIBUS PA is used <strong>in</strong> the field of process <strong>automation</strong> andits special characteristics are power supply over bus and <strong>in</strong>tr<strong>in</strong>sicsafety.Depend<strong>in</strong>g on the <strong>data</strong> rate, the maximum segment lengths <strong>for</strong>cable type A are as follows:Data rate kbit/s9.6 19.2 93.75 187.5 500 1500 3000 6000 12000Segment length (m)1200 1200 1200 1000 400 200 100 100 100The <strong>transmission</strong> technology used MBP (Manchester CodedBus Powered). MBP is synchronous <strong>transmission</strong> with a fixed<strong>transmission</strong> rate of 31.25 kbit/s and Manchester-II cod<strong>in</strong>g. The<strong>in</strong>tr<strong>in</strong>sically safe PROFIBUS PA is connected to the PROFIBUS DPvia segments couplers or l<strong>in</strong>ks.Synopsis of Transmission Media PROFIBUSMBP RS485 RS485-IS Optical fiberData <strong>transmission</strong>digital,Manchester Cod<strong>in</strong>gdigital,NRZ 6 cod<strong>in</strong>g, RS485digital,NRZ 6 cod<strong>in</strong>g, RS485optical,NRZ 6 cod<strong>in</strong>gTransmission rate 31.25 kbit/s 9.6 – 12000 kbit/s 9.6 – 1500 kbit/s 9.6 – 12000 kbit/sCable1-pair cable,twisted and shieldedType A1-pair cable,twisted and shieldedType A1-pair cable,twisted and shieldedType Amulti- and s<strong>in</strong>glemodefiberwith glass,plastic fiber (POF)Power supply via bus l<strong>in</strong>e optionallyvia additional coresoptionallyvia additional coresoptionallyvia additional coresIgnition protection type EEx ia/ib no EEx ia/ib noNetwork topology L<strong>in</strong>e and tree structure L<strong>in</strong>e structure L<strong>in</strong>e structure L<strong>in</strong>e-, star- andr<strong>in</strong>g structureNumber of participants max. 32 per segment,max. 126 per networkmax. 32 per segment,max. 126 per networkmax. 32 per segment,max. 126 per networkmax. 126 per networkRepeatermax. 32 per segment,max. 126 per networkmax. 9 with signalrefreshmax. 9 with signalrefreshunlimited with signal refresh(depend<strong>in</strong>g on thetime delay of signal)6Non-Return-to-Zero

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!