13.07.2015 Views

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

Cables for data transmission in industrial automation - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

70Abbreviationswww.leoni-<strong>in</strong>dustrial-projects.comType designations <strong>for</strong> copper and GigaL<strong>in</strong>e® fiberoptic cablesThe abbreviations used by <strong>LEONI</strong> <strong>for</strong> cables and construction elements referas far as possible to DIN VDE standards.0 Fiber optic communication cable KL0 Fiber optic communication cable KL1 Indoor cableOutdoor cable, breakoutIAT1 Outdoor cableUniversal cableAU2 Semi-loose tubeVFilled loose tubeD3 Non-metallic stra<strong>in</strong> relief elements (ZN)2 Filled loose tube D3 Fill<strong>in</strong>g compound <strong>in</strong> cable coreFWater block<strong>in</strong>g material <strong>in</strong> cable coreQ4 Halogen-free flame-retardant sheath Hof basic element (AT only)5 Halogen-free flame-retardant sheath H6 Number of fibers/number of loose tubes x numbernnxmof fibers per loose tube7 Multimode fiberS<strong>in</strong>glemode fiberGE8 Core diameter <strong>in</strong> µm (multimode fiber)Field diameter <strong>in</strong> µm (s<strong>in</strong>glemode fiber)9 Cladd<strong>in</strong>g diameter <strong>in</strong> µm10 Attenuation coefficient <strong>in</strong> dB/km11 WavelengthB = 850 nmF = 1,300/1,310 nmH = 1,550 nmBFH12 Bandwidth <strong>in</strong> MHz <strong>for</strong> 1 km <strong>in</strong> the case ofmultimode fibers, dispersion parameter <strong>in</strong>ps/nm <strong>for</strong> 1 km <strong>in</strong> the case of s<strong>in</strong>glemodefibers4 Non-metallic stra<strong>in</strong> relief elementsNon-metallic stra<strong>in</strong> relief elementsand rodent protection elements5 Corrugated steel sheathArmourOuter sheath made of PELayered sheathHalogen-free flame-retardant outer sheathsuitable <strong>for</strong> direct burialHalogen-free flame-retardant outer sheath6 Number of fibers/number of loosetubes x number of fibers per loose tuber7 Multimode fiberS<strong>in</strong>glemode fiber8 Core diameter <strong>in</strong> µm (multimode fiber)Field diameter <strong>in</strong> µm (s<strong>in</strong>glemode fiber)9 Cladd<strong>in</strong>g diameter <strong>in</strong> µm10 Attenuation coefficient <strong>in</strong> dB/km11 WavelengthB = 850 nmF = 1,300/1,310 nmH = 1,550 nm12 Bandwidth <strong>in</strong> MHz <strong>for</strong> 1 km <strong>in</strong> the caseof multimode fibers, dispersion parameter<strong>in</strong> ps/nm <strong>for</strong> 1 km <strong>in</strong> the case of s<strong>in</strong>glemodefibers(ZN)(ZN)BWB2Y(L)2YHcHnnxmGEBFH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!