13.07.2015 Views

Reactive Power Controller Operating instructions

Reactive Power Controller Operating instructions

Reactive Power Controller Operating instructions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Reactive</strong> <strong>Power</strong> <strong>Controller</strong>Switching outputsThe reactive powercontroller Prophi canbe equipped with up to12 switching outputs.Switching outputsExample 1: Prophi with 12 relay outputs10 of the 12 existing outputs shall be engaged.The programming and indication of the switching outputsis carried out in the menu standard programming.The switching outputs can be equipped with either relayor transistor outputs.If a device is equipped with relay or transistor outputsit cannot be read on display. The equipment can onlybe seen on the back side of Prophi in the connectionexample.Prophi is available in three varieties regarding theswitching outputs.1. Only relay outputs2. Only transistor outputs3. Relay and transistor outputs mixedPlease select the indicationof the switchingoutputs using key 1.The automatic symboldisappears.Please select the digitto be changed usingkey 2. The selecteddigit is flashing.Change the selecteddigit by pressing key 3.ϕ1 ϕ2 learn 1:1... ProgSwitching outputsAutomaticIn the menus of the standard programming, only thevariations 1 and 2 can be programmed.In mixed operation the switching outputs with smallernumbers are always the relay outputs.The relay outputs in mixed operation are programmedin the menu of standard programming, and the transistoroutputs are programmed in the menu of expandedprogramming. The programming of the transistor outputsis carried out indirectly via the stage power of theswitching outputs. For transistor outputs, to which nosemiconductor switch is connected, a capacitor powerof 0kvar is set.Switching outputsVariety 1 2 3 4 5 6 7 8 9 10 11 123R R R R3T T T T6R R R R R R R6T T T T T T T6R6T R R R R R R T T T T T T12R R R R R R R R R R R R R12T T T T T T T T T T T T TExample 2: Prophi with 3 transistor outputsPlease check, if 3 transistor outputs are programmed.The programming and indication of the switching outputsis carried out in the menu standard programming.Please go to the indicationof the number ofstages.The automatic symboldisappears.Only two stages areprogrammed!Select the digit to bechanged using key 2.The selected digit isflashing.Change the selecteddigit using key 3.ϕ1 ϕ2 learn 1:1... ProgSwitching outputsAutomaticT= Transistor outputsR= Relay outputsDiagr. Varieties of the switching outputs= Key 1 = Key 2 = Key 3Page 23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!